This paper reports the detailed measurement of the film cooling effectiveness for a scaled up film-cooling hole with an expanded exit fed by a smooth and ribbed secondary flow channel, which is an arrangement typical of turbine blades. The experiments are carried out at blowing ratios ranging from 0.4 to 1.25, and ten different rib patterns, including forward oriented ribs and inverse oriented ribs, are evaluated. Furthermore, in order to develop an efficient film-cooling technique, several kinds of bumps are installed downstream of the hole exits and the effects of the bumps on the film cooling effectiveness are investigated. The bump structures tested here are semicircular, hemispherical, and cylindrical bumps. The results show that the rib orientation strongly affects the film cooling effectiveness. When the blowing ratio is comparatively low, the forward oriented ribs afford a higher film cooling effectiveness. On the contrary, when the blowing ratio is comparatively high, the inverse oriented ribs afford a higher film cooling effectiveness. The cylindrical bump provides a better spreading of the ejected secondary flow than the other bumps, leading to a higher film cooling effectiveness. To clarify how the bumps improve the film cooling effectiveness, computational simulations are performed. The simulations indicate that a longitudinal vortex, formed at the trailing edge of the cylindrical bump, improves the film cooling effectiveness by generating downward velocity vectors.
Skip Nav Destination
Article navigation
Research-Article
Experimental Study on Effects of Internal Ribs and Rear Bumps on Film Cooling Effectiveness
Eiji Sakai,
Toshihiko Takahashi,
Yukiko Agata
Yukiko Agata
e-mail: agata@criepi.denken.or.jp
Central Research Institute of Electric
Power Industry
, Japan
,2-6-1 Nagasaka, Yokosuka-shi
,Kanagawa-ken 240-0196
, Japan
Search for other works by this author on:
Eiji Sakai
e-mail: e-sakai@criepi.denken.or.jp
Toshihiko Takahashi
e-mail: tosihiko@criepi.denken.or.jp
Yukiko Agata
e-mail: agata@criepi.denken.or.jp
Central Research Institute of Electric
Power Industry
, Japan
,2-6-1 Nagasaka, Yokosuka-shi
,Kanagawa-ken 240-0196
, Japan
Contributed by the International Gas Turbine Institute (IGTI) of ASME for publication in the Journal of Turbomachinery. Manuscript received July 2, 2012; final manuscript received July 29, 2012; published online March 25, 2013. Editor: David Wisler.
J. Turbomach. May 2013, 135(3): 031025 (14 pages)
Published Online: March 25, 2013
Article history
Received:
July 2, 2012
Revision Received:
July 29, 2012
Citation
Sakai, E., Takahashi, T., and Agata, Y. (March 25, 2013). "Experimental Study on Effects of Internal Ribs and Rear Bumps on Film Cooling Effectiveness." ASME. J. Turbomach. May 2013; 135(3): 031025. https://doi.org/10.1115/1.4007546
Download citation file:
Get Email Alerts
Related Articles
An Energy-Based Method for Predicting the Additive Effect of Multiple Film Cooling Rows
J. Eng. Gas Turbines Power (December,2015)
Reverse-Pass Cooling Systems for Improved Performance
J. Turbomach (November,2014)
Effects of Inclination Angle, Orientation Angle, and Hole Length on Film Cooling Effectiveness of Rectangular Diffusion Holes
J. Turbomach (July,2018)
Evaluation of Superposition Predictions for Showerhead Film Cooling on a Vane
J. Turbomach (April,2015)
Related Chapters
A Computationally Efficient Algorithm for Modeling Multi-Regime Delays in the Sensory Flow of Networked Telerobots*
International Conference on Advanced Computer Theory and Engineering, 5th (ICACTE 2012)
Experimental Investigation of Ventilated Supercavitation Under Unsteady Conditions
Proceedings of the 10th International Symposium on Cavitation (CAV2018)
Flow Enhancement and Cavitation Suppression in Nozzle Flow by Viscoelastic Additives
Proceedings of the 10th International Symposium on Cavitation (CAV2018)