The amount of clamp load due to an externally applied separating force is determined for a boiled assembly in which the fastener is elongated past its proportional limit, while the clamped joint remained within its elastic range. After the initial tightening of the fastener, the joint is subsequently subjected to a tensile separating force, which further increases the fastener tensile stress into the nonlinear range. Such separating force will simultaneously reduce the clamping force in the bolted joint. Upon the removal of the separating service load, the bolted joint system reaches a new equilibrium point between the fastener tension and the joint clamping force. At the new equilibrium point, the fastener tension is reduced from its value at initial assembly, due to the plastic elongation of the fastener. The reduction in fastener tension translates into a partial—yet permanent—loss of the clamping load that may lead to joint leakage, loosening, or fatigue failure. A nonlinear model is established in order to describe the fastener behavior past the proportional limit of its material, and to determine the clamp load loss due to the permanent set in the fastener after the separating force has been removed. Two fastener materials with significantly different rates of strain hardening are used for modeling the behavior of the bolted joint system. The effect of three nondimensional variables on the amount of clamp load loss is investigated. The first variable is the stiffness ratio of the joint and the fastener. The second is the ratio of initial fastener tension to the fastener elastic limit, and the third variable is the ratio of the separating force to the force that causes joint separation to start. Analytical results are presented for a range of stiffness ratios that simulates both soft and hard joint applications. Experimental verification of the analytical results is presented.
Skip Nav Destination
Article navigation
August 2006
Research Papers
Clamp Load Loss due to Fastener Elongation Beyond its Elastic Limit
Sayed A. Nassar,
Sayed A. Nassar
Fastening and Joining Research Institute, Department of Mechanical Engineering,
Oakland University
, Rochester, Michigan 48309
Search for other works by this author on:
Payam H. Matin
Payam H. Matin
Fastening and Joining Research Institute, Department of Mechanical Engineering,
Oakland University
, Rochester, Michigan 48309
Search for other works by this author on:
Sayed A. Nassar
Fastening and Joining Research Institute, Department of Mechanical Engineering,
Oakland University
, Rochester, Michigan 48309
Payam H. Matin
Fastening and Joining Research Institute, Department of Mechanical Engineering,
Oakland University
, Rochester, Michigan 48309J. Pressure Vessel Technol. Aug 2006, 128(3): 379-387 (9 pages)
Published Online: August 5, 2005
Article history
Received:
June 23, 2004
Revised:
August 5, 2005
Citation
Nassar, S. A., and Matin, P. H. (August 5, 2005). "Clamp Load Loss due to Fastener Elongation Beyond its Elastic Limit." ASME. J. Pressure Vessel Technol. August 2006; 128(3): 379–387. https://doi.org/10.1115/1.2217971
Download citation file:
Get Email Alerts
The Behavior of Elbow Elements at Pure Bending Applications Compared to Beam and Shell Element Models
J. Pressure Vessel Technol (February 2025)
Related Articles
Effect of Separating Load Eccentricity on the Clamp Load Loss in a Bolted Joint Using a Strain Hardening Model
J. Pressure Vessel Technol (April,2011)
Nonlinear Strain Hardening Model for Predicting Clamp Load Loss in Bolted Joints
J. Mech. Des (November,2006)
Cumulative Clamp Load Loss Due to a Fully Reversed Cyclic Service Load Acting on an Initially Yielded Bolted Joint System
J. Mech. Des (April,2007)
Ultrasonic Control of Fastener Tightening Using Varying Wave Speed
J. Pressure Vessel Technol (August,2006)
Related Proceedings Papers
Related Chapters
Analysis of Fastener Tension and Clamping Strain
Structural Shear Joints: Analyses, Properties and Design for Repeat Loading
Strain Hardening and Tensile Properties
New Advanced High Strength Steels: Optimizing Properties
Subsection NG — Core Support Structures
Companion Guide to the ASME Boiler and Pressure Vessel Code, Volume 1, Third Edition