A bolted connection consisting of a cover on a pressure vessel flange with a metallic flat gasket on raised faces is analyzed as a four-body contact problem using axisymmetrical theory of elasticity. The contact stress distribution, the load factor (the relationship between an increment of bolt axial force and an internal pressure), and the gasket properties (the gasket seating width and the moment arm) are examined. In the analysis, the cover is replaced with a finite solid cylinder. The metallic flat gasket, the flange, and the hub are replaced with finite solid cylinders. The effects of the stiffness and the thickness of various size gaskets on the contact stress distribution are obtained by numerical calculations. Experiments were carried out to obtain the load factor, the maximum stress produced in bolts, and the stress produced on the hub. The analytical results obtained are shown to be consistent with the experimental results.
Skip Nav Destination
Article navigation
August 1997
Research Papers
A Stress Analysis of a Taper Hub Flange With a Bolted Flat Cover
T. Sawa,
T. Sawa
Department of Mechanical Engineering, Yamanashi University, 4-3-11 Takeda, Kofu, Yamanashi Japan
Search for other works by this author on:
N. Higurashi,
N. Higurashi
Ishikawajima Harima Heavy Industry Co. Ltd, Tokyo, 100 Japan
Search for other works by this author on:
T. Hirose
T. Hirose
Kobe Steel Co. Ltd., Tokyo, 100 Japan
Search for other works by this author on:
T. Sawa
Department of Mechanical Engineering, Yamanashi University, 4-3-11 Takeda, Kofu, Yamanashi Japan
N. Higurashi
Ishikawajima Harima Heavy Industry Co. Ltd, Tokyo, 100 Japan
T. Hirose
Kobe Steel Co. Ltd., Tokyo, 100 Japan
J. Pressure Vessel Technol. Aug 1997, 119(3): 293-300 (8 pages)
Published Online: August 1, 1997
Article history
Received:
September 9, 1991
Revised:
January 31, 1997
Online:
February 11, 2008
Citation
Sawa, T., Higurashi, N., and Hirose, T. (August 1, 1997). "A Stress Analysis of a Taper Hub Flange With a Bolted Flat Cover." ASME. J. Pressure Vessel Technol. August 1997; 119(3): 293–300. https://doi.org/10.1115/1.2842307
Download citation file:
Get Email Alerts
Cited By
Related Articles
Stress Analysis and Determination of Bolt Preload in Pipe Flange Connections With Gaskets Under Internal Pressure
J. Pressure Vessel Technol (November,2002)
Design for Leakage in Flange Joints Under External Loads
J. Pressure Vessel Technol (May,2007)
A Stress Analysis of Pipe Flange Connections
J. Pressure Vessel Technol (November,1991)
On the Characteristics of Rectangular Bolted Flanged Connections With Gaskets Subjected to External Tensile Loads and Bending Moments
J. Pressure Vessel Technol (May,1994)
Related Proceedings Papers
Related Chapters
Standardization of Valves, Flanges, Fittings and Gaskets (ASME B16 Standard)
Continuing and Changing Priorities of the ASME Boiler & Pressure Vessel Codes and Standards
Part 2, Section II—Materials and Specifications
Companion Guide to the ASME Boiler and Pressure Vessel Code, Volume 1, Fourth Edition
Background Information
Guidebook for the Design of ASME Section VIII Pressure Vessels, Third Edition