At present, most of the orthopaedic implants used in articular reconstruction are fixed to host bone using acrylic bone-cement. Bone-cement polymerization leads to an exothermic reaction with heat release and consequent temperature rise. The increase of temperature in the bone beyond the tolerated limits can develop osteocyte thermal necrosis and ultimately lead to bone resorption at the cement-bone interface, with subsequent loosening of the implant. Another issue that plays an important role in implant loosening is debonding of the cement from the implant initiated by crack formation at the interfacial voids. It is well established that low porosity enables better fatigue cement properties. Moderate preheating of the implant is expected to reverse the direction of polymerization, and has the ability to reduce interfacial void formation and improve interfacial shear strength. To increase the implant temperature at the initial cementing phase in order to reduce interfacial void formation, and subsequently, cool the implant in the latter cement polymerization phase to prevent the possibility of bone thermal necrosis, a new automated electronic device was designed to be use in cemented joint replacements. The developed device was specifically designed for the knee arthroplasty, namely for tibial-tray cementing. The device controls the heat flux direction between the tibial-tray and the atmosphere through the “Peltier effect,” using Peltier tablets. The device is placed on the tibial-tray during the cementing phase and starts to heat it in a first phase, promoting the polymerization that initiates at the warmer cement-implant interface. In a second phase, the heat flux in the Peltier tablets is inverted to extract the heat generated during cement polymerization. The device efficiency was evaluated by cementing several tibial-trays in bovine fresh bone and measuring the tray and cement temperatures. The temperature results in the implant and in the cement showed that the device increases and maintains the implant temperature above room temperature at the initial cementing phase, while in the subsequent phase it cools the tibial-tray and cement. Significant differences were found for peak cement temperatures between the tests performed with and without the device. The device showed its capacity to promote the beginning of cement polymerization at the implant interface contributing towards improving interfacial shear strength and in reducing the peak cement temperature in the subsequent polymerization process, thus contributing to the prevention of the bone thermal necrosis effect.

References

1.
Berman
,
A. T.
,
Reid
,
J. S.
,
Yanicko
,
D. R.
Jr.
,
Sih
,
G. C.
, and
Zimmerman
,
M. R.
, 1984, “
Thermally Induced Bone Necrosis in Rabbits. Relation to Implant Failure in Humans
,”
Clin. Orthop.
,
186
, pp.
284
292
.
2.
Lundskog
,
J.
, 1972, “
Heat and Bone Tissue. An Experimental Investigation of the Thermal Properties of Bone and Threshold Levels for Thermal Injury
,”
Scand. J. Plast. Reconstr. Surg.
,
9
, pp.
1
80
.
3.
Eriksson
,
A. R.
,
Albrektsson
,
T.
, 1983, “
Temperature Threshold Levels for Heat-Induced Bone Tissue Injury: A Vital-Microscopic Study in the Rabbit
,”
J. Prosthet. Dent.
,
50
(
1
), pp.
101
107
.
4.
Jasty
,
M.
,
Maloney
,
W. J.
,
Bragdon
,
C. R.
,
O’Connor
,
D. O.
,
Haire
,
T.
,
Harris
,
W. H.
, 1991, “
The Initiation of Failure in Cemented Femoral Components of Hip Arthroplasties
,”
J. Bone Joint Surg. Br.
,
73
, pp.
551
558
.
5.
Verdonschot
,
N.
, and
Huiskes
,
R.
, 1997, “
The Effects of Cement–Stem Debonding in THA on the Long-Term Failure Probability of Cement
,”
J. Biomech.
,
30
, pp.
795
802
.
6.
Lewis
,
G.
, 1997, “
Properties of Acrylic Bone Cement: State of the Art Review
,”
J. Biomed. Mater. Res.
,
38
(
2
), pp.
155
182
.
7.
Klein
,
R. W.
,
Scott
,
C. P.
, and
Higham
,
P. A.
, 2004, “
The Strength of Acrylic Bone Cement Cured under Thumb Pressure
,”
Biomaterials
,
25
(
5
), pp.
943
947
.
8.
Barrack
,
R. L.
,
Mulroy
,
R. D.
Jr.
, and
Harris
,
W. H.
, 1992, “
Improved Cementing Techniques and Femoral Component Loosening in Young Patients with Hip Arthroplasty. A 12-Year Radiographic Review
,”
J. Bone Joint Surg. Br.
,
74
, pp.
385
389
.
9.
Dunne
,
N. J.
, and
Orr
,
J. F.
, 2001, “
Influence of Mixing Techniques on the Physical Properties of Acrylic Bone Cement
,”
Biomaterials
,
22
, pp.
1819
1826
.
10.
James
,
S. P.
,
Schmalzried
,
T. P.
,
McGarry
,
F. J.
, and
Harris
,
W. H.
, 1993, “
Extensive Porosity at the Cement–Femoral Prosthesis Interface: A Preliminary Study
,”
J. Biomed. Mater. Res.
,
27
, pp.
71
78
.
11.
Bishop
,
N. E.
,
Ferguson
,
S.
, and
Tepic
,
S.
, 1996, “
Porosity Reduction in Bone Cement at the Cement–Stem Interface
,”
J. Bone Joint Surg. Br.
,
78
, pp.
349
356
.
12.
Topoleski
,
L. D. T.
,
Ducheyne
,
P.
, and
Cuckler
,
J. M.
, 1993, “
Microstructural Pathway of Fracture in Poly(Methyl Methacrylate) Bone-Cement
,”
Biomaterials
,
14
(
15
), pp.
1165
1172
.
13.
Iesaka
,
K.
,
Jaffe
,
W.
, and
Kummer
,
F. J.
, 2003, “
Effects of Preheating of Hip Prostheses on the Stem–Cement Interface
,”
J. Bone Joint Surg. Am.
,
85
, pp.
421
427
.
14.
Jafri
,
A. A.
,
Green
,
S. M.
,
Partington
,
P. F.
,
McCaskie
,
A. W.
, and
Muller
,
S. D.
, 2004, “
Pre-Heating of Components in Cemented Total Hip Arthroplasty
,”
J. Bone Joint Surg. Br.
,
86
, pp.
1214
1219
.
15.
Hsieh
,
P. H.
,
Tai
,
C. L.
,
Chang
,
Y. H.
,
Lee
,
M. S.
,
Shih
,
H. N.
, and
Shih
,
C. H.
, 2006, “
Precooling of the Femoral Canal Enhances Shear Strength at the Cement-Prosthesis Interface and Reduces the Polymerization Temperature
,”
J. Orthop. Res.
,
24
(
9
), pp.
1809
1814
.
16.
Li
,
C.
,
Schmid
,
S.
, and
Mason
,
J.
, 2003, “
Effects of Pre-Cooling and Pre-Heating Procedures on Cement Polymerization and Thermal Osteonecrosis in Cemented Hip Replacements
,”
Med. Eng. Phys.
,
25
, pp.
559
564
.
17.
Maffezzoli
,
A.
,
Ronca
,
D.
,
Guida
,
G.
,
Pochini
,
I.
, and
Nicolais
,
L.
, 1997, “
In-Situ Polymerization Behaviour of Bone Cements
,”
J. Mater. Sci.: Mater. Med.
,
8
, pp.
75
83
.
18.
Fukushima
,
H.
,
Hashimoto
,
Y.
,
Yoshiya
,
S.
,
Kurosaka
,
M.
,
Matsuda
,
M.
,
Kawamura
,
S.
, and
Iwatsubo
,
T.
, 2002, “
Conduction Analysis of Cement Interface Temperature in total Knee Arthroplasty
,”
Kobe J. Med. Sci.
,
48
(
1–2
), pp.
63
72
.
You do not currently have access to this content.