The long-term outcome of endovascular coiling of cerebral aneurysms is directly related to the packing density at the time of treatment. In general, the highest packing density achievable is only about 45% due to the quasirandom distribution of currently available coils within aneurysms. We investigated whether packing densities could be maximized via more ordered coil configurations. Three different coil configurations—circular loops, planar spirals, and spherical helices—were investigated. The packing densities achievable in maximally filling the volume of an exemplar human basilar aneurysm with each coil configuration were calculated numerically. Coil packing simulations were also carried out for aneurysms idealized as spheres over diameters ranging from 2 mm to 30 mm. The packing densities with the loop, spiral, and spherical helix configurations were 82%, 60%, and 73%, respectively, for the human aneurysm model; the numbers of coils required were 693, 34, and 13, respectively. Simulations within idealized aneurysms suggest that aneurysms cannot be packed to more than 91% with coils of constant circular cross section. The spherical helix configuration provides a constant packing density (coefficient of variation of 0.4%) over the range of aneurysm diameters studied as compared to the two other configurations (coefficients of variation of 9% and 8%). Coil configurations that allow for ordered filling of cerebral aneurysms can potentially provide packing densities that are twice those currently achieved. The spherical helix configuration seems to be the most technically feasible and stable configuration of the three coil types investigated.
Skip Nav Destination
e-mail: blieber@miami.edu
Article navigation
December 2009
Research Papers
Numerical Investigation of Coil Configurations That Provide Ultrahigh Packing Density of Saccular Aneurysms
Chander Sadasivan,
Chander Sadasivan
Department of Biomedical Engineering,
University of Miami
, Coral Gables, FL 33146
Search for other works by this author on:
Baruch B. Lieber
Baruch B. Lieber
Professor
Department of Biomedical Engineering and Department of Radiology,
e-mail: blieber@miami.edu
University of Miami
, Miami, FL 33146
Search for other works by this author on:
Chander Sadasivan
Department of Biomedical Engineering,
University of Miami
, Coral Gables, FL 33146
Baruch B. Lieber
Professor
Department of Biomedical Engineering and Department of Radiology,
University of Miami
, Miami, FL 33146e-mail: blieber@miami.edu
J. Med. Devices. Dec 2009, 3(4): 041005 (5 pages)
Published Online: November 20, 2009
Article history
Received:
June 25, 2009
Revised:
October 1, 2009
Online:
November 20, 2009
Published:
November 20, 2009
Citation
Sadasivan, C., and Lieber, B. B. (November 20, 2009). "Numerical Investigation of Coil Configurations That Provide Ultrahigh Packing Density of Saccular Aneurysms." ASME. J. Med. Devices. December 2009; 3(4): 041005. https://doi.org/10.1115/1.4000453
Download citation file:
Get Email Alerts
Cited By
Related Articles
Adult Male Circumcision Device for Use in Clinical Settings
J. Med. Devices (June,2011)
Design of a Mobile Head Support Based on a Compliant Mechanism
J. Med. Devices (June,2011)
Ambulatory Device for Urinary Incontinence Detection in Female Athletes
J. Med. Devices (June,2009)
Adult Male Circumcision Tool for Use in Traditional Ceremonies
J. Med. Devices (June,2010)
Related Proceedings Papers
Related Chapters
The Thermo —Mechanical Analysis of Mechanical Packing (SEAL), Using Finite Element Method (FEM) — Results and Conclusions
International Conference on Mechanical Engineering and Technology (ICMET-London 2011)
Natural Gas Transmission
Pipeline Design & Construction: A Practical Approach, Third Edition
Optimization of an Irregular 2D Packing Problem by a Genetic-Based Heuristic Algorithm
International Conference on Computer and Automation Engineering, 4th (ICCAE 2012)