The long-term outcome of endovascular coiling of cerebral aneurysms is directly related to the packing density at the time of treatment. In general, the highest packing density achievable is only about 45% due to the quasirandom distribution of currently available coils within aneurysms. We investigated whether packing densities could be maximized via more ordered coil configurations. Three different coil configurations—circular loops, planar spirals, and spherical helices—were investigated. The packing densities achievable in maximally filling the volume of an exemplar human basilar aneurysm with each coil configuration were calculated numerically. Coil packing simulations were also carried out for aneurysms idealized as spheres over diameters ranging from 2 mm to 30 mm. The packing densities with the loop, spiral, and spherical helix configurations were 82%, 60%, and 73%, respectively, for the human aneurysm model; the numbers of coils required were 693, 34, and 13, respectively. Simulations within idealized aneurysms suggest that aneurysms cannot be packed to more than 91% with coils of constant circular cross section. The spherical helix configuration provides a constant packing density (coefficient of variation of 0.4%) over the range of aneurysm diameters studied as compared to the two other configurations (coefficients of variation of 9% and 8%). Coil configurations that allow for ordered filling of cerebral aneurysms can potentially provide packing densities that are twice those currently achieved. The spherical helix configuration seems to be the most technically feasible and stable configuration of the three coil types investigated.

1.
Raymond
,
J.
,
Guilbert
,
F.
,
Weill
,
A.
,
Georganos
,
S. A.
,
Juravsky
,
L.
,
Lambert
,
A.
,
Lamoureux
,
J.
,
Chagnon
,
M.
, and
Roy
,
D.
, 2003, “
Long-term Angiographic Recurrences After Selective Endovascular Treatment of Aneurysms With Detachable Coils
,”
Stroke
0039-2499,
34
, pp.
1398
1403
.
2.
Tamatani
,
S.
,
Ito
,
Y.
,
Abe
,
H.
,
Koike
,
T.
,
Takeuchi
,
S.
, and
Tanaka
,
R.
, 2002, “
Evaluation of the Stability of Aneurysms After Embolization Using Detachable Coils: Correlation Between Stability of Aneurysms and Embolized Volume of Aneurysms
,”
AJNR Am. J. Neuroradiol.
0195-6108,
23
, pp.
762
767
.
3.
Sluzewski
,
M.
,
van Rooij
,
W. J.
,
Slob
,
M. J.
,
Bescós
,
J. O.
,
Slump
,
C. H.
, and
Wijnalda
,
D.
, 2004, “
Relation between Aneurysm Volume, Packing, and Compaction in 145 Cerebral Aneurysms Treated With Coils
,”
Radiology
0033-8419,
231
, pp.
653
658
.
4.
Yagi
,
K.
,
Satoh
,
K.
,
Satomi
,
J.
,
Matsubara
,
S.
, and
Nagahiro
,
S.
, 2005, “
Evaluation of Aneurysm Stability After Endovascular Embolization With Guglielmi Detachable Coils: Correlation Between Long-Term Stability and Volume Embolization Ratio
,”
Neurol. Med. Chir. (Tokyo)
0387-2572,
45
, pp.
561
565
.
5.
Vallée
,
J. N.
,
Pierot
,
L.
,
Mont'alverne
,
F.
,
Turjman
,
F.
,
Bonafé
,
A.
,
Bracard
,
S.
,
Lo
,
D.
,
Crozier
,
S.
,
Duffau
,
H.
,
Barragan-Campos
,
H. M.
,
Jean
,
B.
,
Guillevin
,
R.
, and
Chiras
,
J.
, 2005, “
Unruptured Intracranial Aneurysms Treated by Three-Dimensional Coil Embolization: Evaluation of the Postoperative Aneurysm Occlusion Volume
,”
Neuroradiology
0028-3940,
47
, pp.
438
445
.
6.
Piotin
,
M.
,
Iijima
,
A.
,
Wada
,
H.
, and
Moret
,
J.
, 2003, “
Increasing the Packing of Small Aneurysms With Complex-Shaped Coils: An In Vitro Study
,”
AJNR Am. J. Neuroradiol.
0195-6108,
24
, pp.
1446
1448
.
7.
van Rooij
,
W. J.
, and
Sluzewski
,
M.
, 2007, “
Packing Performance of GDC 360 Degrees Coils in Intracranial Aneurysms: A Comparison With Complex Orbit Coils and Helical GDC 10 Coils
,”
AJNR Am. J. Neuroradiol.
0195-6108,
28
, pp.
368
370
.
8.
Slob
,
M. J.
,
van Rooij
,
W. J.
, and
Sluzewski
,
M.
, 2005, “
Influence of Coil Thickness on Packing, Re-Opening and Retreatment of Intracranial Aneurysms: A Comparative Study Between Two Types of Coils
,”
Neurol. Res.
0160-6412,
27
, pp.
116
119
.
9.
Wakhloo
,
A. K.
,
Gounis
,
M. J.
,
Sandhu
,
J. S.
,
Akkawi
,
N.
,
Schenck
,
A. E.
, and
Linfante
,
I.
, 2007, “
Complex-Shaped Platinum Coils for Brain Aneurysms: Higher Packing Density, Improved Biomechanical Stability, and Midterm Angiographic Outcome
,”
AJNR Am. J. Neuroradiol.
0195-6108,
28
, pp.
1395
1400
.
10.
Bendok
,
B. R.
,
Parkinson
,
R. J.
,
Hage
,
Z. A.
,
Adel
,
J. G.
, and
Gounis
,
M. J.
, 2007, “
The Effect of Vascular Reconstruction Device-Assisted Coiling on Packing Density, Effective Neck Coverage, and Angiographic Outcome: An In Vitro Study
,”
Neurosurgery
0148-396X,
61
, pp.
835
840
.
11.
Li
,
C.
,
Xu
,
C.
,
Gui
,
C.
, and
Fox
,
M. D.
, 2005, “
Level Set Evolution Without Re-Initialization: A New Variational Formulation
,”
Proceedings of the IEEE Computer Society Conference on Computer Vision and Pattern Recognition
,
1
, pp.
430
436
.
12.
Löhner
,
R.
, and
Onate
,
E.
, 2004, “
A General Advancing Front Technique for Filling Space With Arbitrary Objects
,”
Int. J. Numer. Methods Eng.
0029-5981,
61
, pp.
1977
1991
.
13.
Szpiro
,
G. G.
, 2003,
Kepler’s Conjecture
,
Wiley
,
Hoboken, NJ
, pp.
234
238
.
14.
van Rooij
,
W. J.
, and
Sluzewski
,
M.
, 2009, “
Endovascular Treatment of Large and Giant Aneurysms
,”
AJNR Am. J. Neuroradiol.
0195-6108,
30
, pp.
12
18
.
You do not currently have access to this content.