A procedure for manufacturing cardiovascular system models using patient-specific data, rapid prototyping, and a multistep dip-spin coating process is presented here. Improvements to a previously developed process permitted the fabrication of flexible complex vascular replicas. The primary improvement included the development of a two-axis rotation mechanism that enabled a pseudorandom rotation of the coated mold in space, providing uniform coats. Other improvements included the use of a low viscosity (15002000cP) silicone solution that allowed for complete coverage of the mold, and developing a procedure for fixing defects. The dip-spin coating procedure was shown to be effective for the manufacture of compliant cardiovascular membranes, such as an arterial bypass graft with an internal flow passage and an abdominal aorta with nonuniform radial geometry, tapered diameters, bifurcations, and small branches. Results from a design of experiments comparing two dipping setups demonstrated that horizontally dipping the model produced coatings with more uniform thicknesses along the length of the model when compared to vertical dipping. For a 250-mm-long model, the difference in thickness between the top and bottom of the membrane was 0.42±0.069mm and 0.09±0.077mm for vertical and horizontal dippings, respectively. Mold diameter also affected the thickness of the membrane, with membrane thickness increasing as mold diameter decreased. Thickness data comparing locations at approximately the same height of the mold but with different diameters showed thicknesses of 2.54±0.198mm and 1.95±0.140mm for 7.85mm and 15.20mm diameters, respectively. Moreover, the differences in thickness between these locations were 0.60±0.128mm and 0.58±0.231mm for vertical and horizontal dippings, respectively; thus, membrane thickness variations occurred with mold diameter irrespective of the dipping setup. Depending on the prescribed tolerance for membrane thickness, the vertical dipping setup may be recommended for use because (1) it was easier to use since only the mold was immersed in the coating solution and no special protection of the dipping mechanism was required and (2) it produced fewer defects in the coatings since the solution always dripped from downfacing surfaces of the mold. Using this dip-spin coating procedure, patient-specific cardiovascular membranes can be manufactured and used in the development of medical devices, research requiring accurate anatomical models, and education and training.

1.
American Heart Association
, 2002,
Heart Disease and Stroke Statistics: 2003 Update
,
American Heart Association
,
Dallas, TX
.
2.
Shipkowitz
,
T.
,
Rodgers
,
V. G. J.
,
Franzin
,
L. J.
, and
Chandran
,
K. B.
, 2000, “
Numerical Study on the Effect of Secondary Flow in the Human Aorta on Local Shear Stresses in Abdominal Aortic Branches
,”
J. Biomech.
0021-9290,
33
, pp.
717
728
.
3.
Weydahl
,
E. S.
, and
Moore
,
J. E.
, Jr.
, 2001, “
Dynamic Curvature Strongly Affects Wall Shear Rates in a Coronary Artery Bifurcation Model
,”
J. Biomech.
0021-9290,
34
, pp.
1189
1196
.
4.
Liepsch
,
D.
, 2002, “
An Introduction to Biofluid Mechanics: Basic Models and Applications
,”
J. Biomech.
0021-9290,
35
, pp.
415
435
.
5.
Taylor
,
C. A.
,
Cheng
,
C. P.
,
Espinosa
,
L. A.
,
Tang
,
B. T.
,
Parker
,
D.
, and
Herfkens
,
R. J.
, 2002, “
In Vivo Quantification of Blood Flow and Wall Shear Stress in the Human Abdominal Aorta During Lower Limb Exercise
,”
Ann. Biomed. Eng.
0090-6964,
30
, pp.
402
408
.
6.
Markl
,
M.
,
Chan
,
F. P.
,
Alley
,
M. T.
,
Wedding
,
K. L.
,
Draney
,
M. T.
,
Elkins
,
C. J.
,
Parker
,
D. W.
,
Wicker
,
R. B.
,
Taylor
,
C. A.
,
Herfkens
,
R. J.
, and
Pelc
,
N. J.
, 2003, “
Time-Resolved Three-Dimensional Phase-Contrast MRI
,”
J. Magn. Reson Imaging
1053-1807,
17
, pp.
499
506
.
7.
Elkins
,
C. J.
,
Alley
,
M. T.
,
Yamauchi
,
A.
, and
Wicker
,
R. B.
, 2006, “
MRV Flow Studies in End-to-Side Anastomosis Bypass Graft Phantoms
,” BIO2006-1572992006
ASME Summer Bioengineering Conference
,
Amelia Island Plantation
,
Amelia Island, FL
, June 21–25, Paper No. BIO2006-1572992006.
8.
Van der Steen
,
A. F. W.
,
Cespedes
,
E. I.
,
Carlier
,
S. G.
,
Mastik
,
F.
,
Lupotti
,
F.
,
Borsboom
,
J. M. G.
,
Li
,
W.
,
Serruys
,
P. W.
, and
Bom
,
N.
, 2000, “
Flow Estimation Using an Intravascular Image Catheter
,”
Ultrasonics
0041-624X,
38
, pp.
363
368
.
9.
Krams
,
R.
,
Wentzel
,
J. J.
,
Cespedes
,
I.
,
Vinke
,
R.
,
Carlier
,
S.
,
van der Steen
,
A. F. W.
,
Lancee
,
C. T.
, and
Slager
,
C. J.
, 1999, “
Effect of Catheter Placement on 3-D Velocity Profiles in Curved Tubes Resembling the Human Coronary System
,”
Ultrasound Med. Biol.
0301-5629,
25
(
5
), pp.
803
810
.
10.
Wanitkun
,
S.
,
Gharib
,
M.
, and
Zarandi
,
M.
, 1999, “
Evaluation of Descending Aortic Flow Volumes and Effective Orifice Area Through Aortic Coarctation by Spatiotemporal Integration of Color Doppler Data: An In-Vitro Study
,”
J. Am. Soc. Echocardiogr
0894-7317,
12
, pp.
517
526
.
11.
Johnson
,
L. R.
, and
Shanebrook
,
J. R.
, 1995, “
Flow Visualization With Air and Smoke in a Bypass Graft Model Under Steady Flow Conditions
,”
J. Biomech.
0021-9290,
28
(
10
), pp.
1237
1241
.
12.
Seifert
,
B. I.
,
DesRochers
,
K.
,
Ta
,
M.
, and
Giraud
,
G.
, 1999, “
Accuracy of Doppler Methods for Estimating Peak-to-Peak Instantaneous Gradients Across Coarctation of the Aorta: An In Vitro Study
,”
J. Am. Soc. Echocardiogr
0894-7317,
12
, pp.
744
753
.
13.
Stevanov
,
M.
,
Baruthio
,
J.
, and
Eclancher
,
B.
, 2000, “
Fabrication of Elastomer Arterial Models With Specified Compliance
,”
J. Appl. Physiol.
8750-7587,
88
, pp.
1291
1294
.
14.
Dabroski
,
W.
,
Dunmore-Buyze
,
J.
,
Cardinal
,
H. N.
, and
Fenster
,
A.
, 2001, “
A Real Vessel Phantom for Flow Imaging: 3-D Doppler Ultrasound of Steady Flow
,”
Ultrasound Med. Biol.
0301-5629,
27
, pp.
135
141
.
15.
Zarins
,
C. K.
,
Xu
,
C.
, and
Glagov
,
S.
, 2001, “
Atherosclerotic Enlargement of the Human Abdominal Aorta
,”
Atherosclerosis
0021-9150,
155
, pp.
157
164
.
16.
Elkins
,
C. J.
,
Iyengar
,
A. S.
,
Draney
,
M. T.
,
Dake
,
M. D.
,
Medina
,
F.
, and
Wicker
,
R. B.
, 2005, “
Rapid In-Vitro MRV and PIV Measurements in Anatomically Accurate Human Thoracic Aorta Phantoms
,”
Proceedings of the 2005 Summer Bioengineering Conference
, Vail, CO, June 22–26.
17.
Elkins
,
C. J.
,
Acosta
,
I.
,
Gonzales
,
M.
,
Medina
,
F.
,
Iyengar
,
A. S.
,
Dake
,
M. D.
, and
Wicker
,
R. B.
, 2005, “
Hemodynamic Studies of Aortic Dissection in Patient-Specific Phantoms
,”
Proceedings of the 2005 Summer Bioengineering Conference
, Vail, CO, June 22–26.
18.
Acosta
,
I.
,
Gonzales
,
M.
,
Medina
,
F.
,
Iyengar
,
A. S.
,
Elkins
,
C. J.
, and
Wicker
,
R. B.
, 2005, “
Manufacturing Patient-Specific Aortic Dissection Flow Phantoms With Compliant Flaps
,”
Proceedings of the 2005 Summer Bioengineering Conference
, Vail, CO, June 22–26.
19.
Palafox
,
G. N.
,
Wicker
,
R. B.
, and
Elkins
,
C. J.
, 2003, “
Rapid In-Vitro Physiologic Flow Experimentation Using Rapid Prototyping and Particle Image Velocimetry
,”
Proceedings of the 2003 Summer Bioengineering Conference
, Key Biscayne, FL, June 25–29, pp.
419
420
.
20.
Hopkins
,
L. M.
,
Kelly
,
J. T.
,
Wexler
,
A. S.
, and
Prasad
,
A. K.
, 2000, “
Particle Image Velocimetry Measurements in Complex Geometries
,”
Exp. Fluids
0723-4864,
29
, pp.
91
95
.
21.
Wicker
,
R.
,
Cortez
,
M.
,
Medina
,
F.
,
Palafox
,
G.
, and
Elkins
,
C.
, 2001, “
Manufacturing of Complex Compliant Cardiovascular System Models for In-Vitro Hemodynamic Experimentation Using CT and MRI Data and Rapid Prototyping Technologies
,”
Proceedings of the 2001 Summer Bioengineering Conference
, Snowbird, UT, June 27–July 1, pp.
469
470
.
22.
Lermursiaux
,
P.
,
Leroux
,
C.
,
Tasse
,
J. C.
,
Castellani
,
L.
, and
Martinez
,
R.
, 2001, “
Aortic Aneurysm: Construction of a Life-Size Model by Rapid Prototyping
,”
Ann. Vasc. Surg.
0890-5096,
15
, pp.
131
135
.
23.
Cortez
,
M. A.
,
Quintana
,
R.
, and
Wicker
,
R. B.
, 2007, “
Multi-Step Dip Spin Coating Manufacturing System for Silicone Cardiovascular Membrane Fabrication with Prescribed Compliance
,”
Int. J. Adv. Manuf. Technol.
0268-3768,
34
(7-8), pp.
667
679
.
24.
Arcaute
,
K.
,
Palafox
,
G. N.
,
Medina
,
F.
, and
Wicker
,
R. B.
, 2003, “
Complex Silicone Aorta Models Manufactured Using a Dip-Spin Coating Technique and Water-Soluble Molds
,”
Proceedings of the 2003 Summer Bioengineering Conference
, Key Biscayne, FL, June 25–29, pp.
1093
1094
.
25.
Medina
,
F.
, and
Wicker
,
R. B.
, 2003, “
Geometric Modeling of the Human Aorta for Rapid Prototyping Using Patient Data and Commercial Software Packages
,”
Proceedings of the 2003 Summer Bioengineering Conference
, Key Biscayne, FL, June 25–29, pp.
421
422
.
26.
Wicker
,
R. B.
, and
Medina
,
F.
, 2003, “
Framework for Physical Modeling of Complex Internal Flow Passages Using Rapid Prototyping and Water-Soluble Molds
,”
Proceedings of the 31st International Conference on Computers and Industrial Engineering
, San Francisco, CA, Feb. 2–4, pp.
559
564
.
27.
Lombardi
,
J.
,
Dragan
,
P.
, and
Gregory
,
J. A.
, 1999, “
Water Soluble Rapid Prototyping Support and Mold Material
,” International Patent Application No. WO 99/60507.
28.
DuPont Dow Elastomers
, 1997, “
Neoprene Latex Dipped Goods
,” DuPont Dow Elastomers, Technical Report No. H-73631.
29.
Arcaute
,
K.
, 2004, “
Complex Silicone Cardiovascular Models Manufactured Using a Dip-Spin Coating Technique and Water-Soluble Molds
,” MS thesis, The University of Texas at El Paso.
30.
Rhodia Inc. Silicones
, 1999, Silbione 40,000 Technical Data Sheet, Rhodia Inc. Silicones (www.rhodia-silicones.comwww.rhodia-silicones.com).
31.
Fish
,
J. G.
, 1982, “
Organic Polymer Coatings
,”
Deposition Technologies for Films and Coatings, Developments and Applications
,
Noyes
,
Park Ridge, NJ
, Sec. 12.
32.
Bunshah
,
R. F.
, 1982, “
Deposition Technologies: An Overview
,”
Deposition Technologies for Films and Coatings, Developments and Applications
,
Noyes
,
Park Ridge, NJ
, Sec. 1.
33.
Cortez
,
M. A.
, 2002, “
Fabrication of Silicone Models of Cardiovascular Systems With Prescribed Compliance
,” MS thesis, The University of Texas at El Paso.
34.
Sonawane
,
R. S.
,
Hegde
,
S. G.
, and
Dongare
,
M. K.
, 2002, “
Preparation of Titanium (IV) Oxide Thin Film Photocatalyst by Sol-Gel Dip Coating
,”
Mater. Chem. Phys.
0254-0584,
77
, pp.
744
750
.
35.
Takahashi
,
Y.
,
Okada
,
S.
,
Bel Hadj Tahar
,
R.
,
Nakano
,
K.
,
Ban
,
T.
, and
Ohya
,
Y.
, 1997, “
Dip-Coating of ITO Films
,”
J. Non-Cryst. Solids
0022-3093,
218
, pp.
134
139
.
36.
Köstlin
,
H.
,
Frank
,
G.
,
Hebbinghaus
,
G.
,
Auding
,
H.
, and
Denissen
,
K.
, 1997, “
Optical Filters on Linear Halogen-Lamps Prepared by Dip-Coating
,”
J. Non-Cryst. Solids
0022-3093,
218
, pp.
347
353
.
37.
Simões
,
A. Z.
,
Gonzalez
,
A. H. M.
,
Zaghete
,
M. A.
,
Cilense
,
M.
,
Varela
,
J. A.
, and
Stojanovic
,
B. D.
, 2001, “
Influence of Viscosity and Ionic Concentration on Morphology of PLZT Thin Films
,”
Appl. Surf. Sci.
0169-4332,
172
, pp.
68
74
.
38.
Eberle
,
A.
, and
Reich
,
A.
, 1997, “
Angle-Dependent Dip-Coating Technique (ADDC) an Improved Method for the Production of Optical Filters
,”
J. Non-Cryst. Solids
0022-3093,
218
, pp.
156
162
.
39.
Pannek
,
M.
,
Dunkel
,
T.
, and
Schubert
,
D. W.
, 2001, “
Effect of a Bell-Shaped Cover in Spin Coating Process on Final Film Thickness
,”
Mater. Res. Innovations
1432-8917,
4
, pp.
340
343
.
40.
Strong
,
A. B.
, 2000,
Plastics: Materials and Processing
, 2nd ed.,
Prentice-Hall
,
Englewood Cliffs, NJ
.
41.
Dušek
,
K.
, and
Dušková-Smrčková
,
M.
, 2000, “
Network Formation During Crosslinking of Organic Coating Systems
,”
Prog. Polym. Sci.
0079-6700,
25
, pp.
1215
1260
.
42.
Ku
,
J. P.
,
Draney
,
M. T.
,
Lee
,
W. A.
,
Arko
,
F.
,
Zarins
,
C. K.
, and
Taylor
,
C. A.
, 2001, “
Comparison of In Vivo MRI Flow Measurements and Predicted Flow Simulation Results
,”
Proceedings of the 2001 Summer Bioengineering Conference
, Snowbird, UT, June 27–July 1, pp.
769
770
.
43.
Ku
,
J. P.
,
Draney
,
M. T.
,
Lee
,
W. A.
,
Arko
,
F.
,
Lee
,
W. A.
,
Chan
,
F. P.
,
Pelc
,
N. J.
,
Zarins
,
C. K.
, and
Taylor
,
C. A.
, 2002, “
In Vivo Validation of Numerial Prediction of Blood Flow in Arterial Bypass Grafts
,”
Ann. Biomed. Eng.
0090-6964,
30
, pp.
743
752
.
44.
Taylor
,
C. A.
,
Parker
,
D.
, and
Wang
,
K. C.
, 2001, “
Image Based Geometric Modeling of the Human Aorta
,”
Proceedings of the 2001 Summer Bioengineering Conference
, Snowbird, UT, June 27–July 1, pp.
623
624
.
You do not currently have access to this content.