Background. One-dimensional regenerator models treat the solid material as a lumped capacitance with negligible temperature gradients. Advanced regenerator geometries operating at low temperatures or active magnetic regenerators which use a liquid heat transfer fluid may have temperature gradients in the solid regenerator that significantly affect performance. It is advantageous to utilize a one-dimensional, or lumped, model of the regenerator that is coupled with a correction factor in order to account for the impact of the internal temperature gradients. Previous work relative to developing such a correction factor is shown here to be inadequate or only valid over a limited range of dimensionless conditions. Method of Approach. This paper describes a numerical model of a sphere subjected to a time varying fluid temperature (representing a passive process) or time varying internal heat generation induced by a magnetic field (representing an active magnetic process). The governing equations are nondimensionalized and the efficiency of the sphere is presented as a function of the Fourier number and Biot number. Results. An approximate correction (or degradation) factor is obtained based on these results that is valid over a wide range of dimensionless conditions and therefore useful to regenerator designers. The degradation factor correlation was developed for a sinusoidal variation in the fluid temperature, however, the same results can be applied to different functional forms of the time variation using the concept of an effective cycle time that is weighted by the magnitude of the driving temperature difference. Conclusions. The heat transfer degradation factor presented here can be applied to one-dimensional regenerator models in order to accurately account for the transient performance of a matrix with finite thermal conductivity. This degradation factor allows regenerator models to approximately account for internal temperature gradients without explicitly modeling them and therefore remain computationally efficient while improving the range of applicability and accuracy.

1.
Fujieda
,
S.
,
Hasegawa
,
Y.
,
Fujita
,
A.
, and
Fukamichi
,
K.
, 2004, “
Thermal Transport Properties of Magnetic Refrigerants La(FexSi1−x) and Their Hydrides, and Gd5Si2Ge2 and MnAs
,”
J. Appl. Phys.
0021-8979,
95
(
5
), pp.
2429
2431
.
2.
Numazawa
,
T.
,
Kamiya
,
K.
,
Satoh
,
T.
,
Nozawa
,
H.
, and
Yanagitani
,
T.
, 2005, “
Status of the Development of Ceramic Regenerator Materials
,”
Proc. 13th Int. Cryocoolers Conf.
, pp.
373
380
.
3.
Engelbrecht
,
K.
,
Nellis
,
G.
, and
Klein
,
S.
, 2005, “
A Numerical Model of an Active Magnetic Regenerator Refrigeration System
,”
Proc. 13th Int. Cryocoolers Conf.
, pp.
471
480
.
4.
Jeffreson
,
C. P.
, 1972, “
Prediction of Breakthrough Curves in Packed Beds: I. Applicability of Single Parameter Models
,”
AIChE J.
0001-1541,
18
, pp.
409
416
.
5.
Hausen
,
H.
, 1983,
Heat Transfer in Counterflow, Parallel-Flow and Cross-Flow
,
McGraw-Hill
, New York.
6.
Hinchcliffe
,
C.
, and
Willmott
,
A. J.
, 1981, “
Lumped Heat-Transfer Coefficients for Thermal Regenerators
,”
Int. J. Heat Mass Transfer
0017-9310,
24
(
7
), pp.
1229
1235
.
7.
Heggs
,
P. J.
, and
Carpenter
,
K. J.
, 1979, “
A Modification of the Thermal Regenerator Infinite Conduction Model to Predict the Effects of Intraconduction
,”
Trans. Inst. Chem. Eng.
0371-7496,
57
(
4
), pp.
228
236
.
8.
Heggs
,
P. J.
,
Bansal
,
L. S.
,
Bond
,
R. S.
, and
Vazakas
,
V.
, 1980, “
Thermal Regenerator Design Charts Including Intraconducton Effects
,”
Trans. Inst. Chem. Eng.
0371-7496,
58
(
4
), pp.
265
270
.
9.
Heggs
,
P. J.
, and
Carpenter
,
K. J.
, 1978, “
Prediction of a Dividing Line Between Conduction and Convection Effects in Regenerator Design
,”
Trans. Inst. Chem. Eng.
0371-7496,
56
(
2
), pp.
86
90
.
10.
Handley
,
D.
, and
Heggs
,
P. J.
, 1968, “
Momentum and Heat Transfer Mechanisms in Regular Shaped Packings
,”
AIChE J.
0001-1541,
46
(
9
), pp.
T251
T263
.
11.
Bradshaw
,
A. V.
,
Johnson
,
A.
,
McLachlan
,
N. H.
, and
Handley
,
, 1970, “
Heat Transfer Between Air and Nitrogen and Packed Beds of Non-Reacting Solids
,”
AIChE J.
0001-1541,
48
(
3
), pp.
T77
T84
.
12.
Heggs
,
P. J.
, and
Sadrameli
,
M.
, 1992, “
Prediction of the Lumped Heat Transfer Coefficient in Regenerators
,” ICHEME Symposium Series No. 129, pp.
377
387
.
13.
Green
,
D. W.
,
Perry
,
P. H.
, and
Babcock
,
R. E.
, 1964, “
Longitudinal Dispersion of Thermal Energy Through Porous Media with a Flowing Fluid
,”
AIChE J.
0001-1541,
10
(
5
), pp.
645
651
.
14.
San
,
J. Y.
, 1993, “
Heat and Mass Transfer in a Two-Dimensional Cross-Flow Regenerator With a Solid Conduction Effect
,”
Int. J. Heat Mass Transfer
0017-9310,
36
(
3
), pp.
633
643
.
15.
Carslaw
,
H. S.
, and
Jaeger
,
J. C.
, 1959,
Conduction of Heat in Solids
, 2nd Ed.,
Oxford University Press
, New York, Chap. 9, p.
238
.
You do not currently have access to this content.