The advanced humid air turbine (AHAT) system improves the thermal efficiency of gas turbine power generation by using a humidifier, a water atomization cooling (WAC) system, and a heat recovery system, thus eliminating the need for an extremely high firing temperature and pressure ratio. The following elemental technologies have been developed to realize the AHAT system: (1) a broad working range and high-efficiency compressor that utilizes the WAC system to reduce compression work, (2) turbine blade cooling techniques that can withstand high heat flux due to high-humidity working gas, and (3) a combustor that achieves both low NOx emissions and a stable flame condition with high-humidity air. A gas turbine equipped with a two-stage radial compressor (with a pressure ratio of 8), two-stage axial turbine, and a reverse-flow type of single-can combustor has been developed based on the elemental technologies described above. A pilot plant that consists of a gas turbine generator, recuperator, humidification tower, water recovery system, WAC system, economizer, and other components is planned to be constructed, with testing slated to begin in October 2006 to validate the performance and reliability of the AHAT system. The expected performance is as follows: thermal efficiency of 43% (LHV), output of 3.6MW, and NOx emissions of less than 10ppm at 15% O2. This paper introduces the elemental technologies and the pilot plant to be built for the AHAT system.

1.
Mori
,
Y.
, and
Nakamura
,
H.
, 1983, “
A Highly Efficient Regenerative Gas Turbine System by New Method of Heat Recovery With Water Injection
,” IGTC, Tokyo.
2.
Rao
,
A. D.
, 1991, “
A Comparison of Humid Air Turbine (HAT) Cycle and Combined-Cycle Power Plants
,” EPRI IE-7300.
3.
Nakhamkin
,
M.
, 1995, “
The Cascaded Humidified Advanced Turbine (CHAT)
,” ASME Cogen-Turbo.
4.
De Ruyck
,
J.
, et al.
, 1997, “
REVAP CYCLE: A New Evaporative Cycle Without Saturation Tower
,”
Trans. of the ASME
,
119
, pp.
893
897
.
5.
van Liere
,
J.
, 1998, “
The TOPHAT Cycle
,” IERE Workshop,
Kobe, Japan
.
6.
Hatamiya
,
S.
, 2002, “
Gas Turbine Power Generation Technology Utilizing High Humidity Air
,”
The Thermal and Nuclear Power
,
53
(
9
), pp.
1031
1038
.
7.
Nakamura
,
H.
, and
Yamamoto
,
K.
, 1992, “
HAT (Humid Air Cycle) Cycle
,”
The Thermal and Nuclear Power
,
43
(
12
), pp.
1587
1592
.
8.
Koganezawa
,
T.
,
Inoue
,
H.
, and
Kobayashi
,
N.
, 2002, “
Experimental Study on Diffusion Flame Combustor for Advanced Humid Air Turbine
,”
JSME Annual Meeting
, Vol.
4
, pp.
187
188
.
9.
Higuchi
,
S.
,
Hatamiya
,
S.
,
Seiki
,
N.
, and
Marushima
,
S.
, 2003, “
A Study of Performance on Advanced Humid Air Turbine Systems
,” IGTC-03 TS-090.
10.
Araki
,
H.
,
Higuchi
,
S.
,
Marushima
,
S.
, and
Hatamiya
,
S.
, 2005, “
Design Study of a Humidification Tower for the Advanced Humid Air Turbine System
,” ASME GT2005–68671.
11.
Numata
,
S.
,
Yokota
,
O.
, and
Hatamiya
,
S.
, 2002, “
Analysis Condensation Heat Transfer to Water Spray for Water Recovery System
,”
JSME 39th National Heat and Mass Transfer Symposium
, pp.
661
662
.
12.
Hatamiya
,
S.
,
Araki
,
H.
, and
Higuchi
,
S.
, 2004, “
An Evaluation of Advanced Humid Air Turbine System With Water Recovery
,” ASME GT2004-54031.
13.
Saitou
,
T.
,
Miura
,
K.
,
Inoue
,
H.
, and
Kobayashi
,
N.
, 2005, “
Performance Demonstration of the Full Size Multi Cluster Combustor for DME under Real Engine Condition
,” ASME GT2005-68647.
You do not currently have access to this content.