Due to the advantage of fuel cells over secondary batteries such as long operation time, many efforts were executed in order to use fuel cells as main power sources of small electronic devices such as laptop computers and mobile phones. For the same reason, fuel cells are promising power sources for the hazardous mission robots. Fuel cells are able to increase their radius action through extension of operation time. Despite this advantage, there still exist technical barriers such as increasing power density, efficient hydrogen storage, and fast startup of the power system. First, in order to increase power density, the united stack including proton exchange membrane fuel cells (PEMFC) and membrane humidifying cells were developed. Also, the hydrogen generating system using NaBH4 solution was employed to store hydrogen effectively. In addition, to shorten start-up time, hybrid control of PEMFC and Li-ion battery was adopted. The approaches mentioned above were evaluated. The developed PEMFC/humidifier stack showed high performance. As compared with full humidification condition by external humidifiers, the performance decrease was only 1% even though hydrogen was not humidified and air was partially humidified. Besides, by integrating the PEMFC and the humidifier into a single stack, considerable space for tubing between them was saved. Also, the hydrogen generator operated well with the PEMFC system and allowed for effective fuel storing and refueling. In addition, due to the efficient hybrid control of PEMFC and battery, start-up time was significantly shortened and capacity of PEMFC was reduced, resulting in compactness of the power system. In conclusion, a 600 W PEMFC power system was developed and successfully operated with the robot. Through development and evaluation of the PEMFC power system, the possibility of PEMFC as a novel power source for the hazardous mission robot was verified.

1.
Xie
,
C.
,
Bostaph
,
J.
, and
Pavio
,
J.
, 2004, “
Development of a 2 W Direct Methanol Fuel Cell Power Source
,”
J. Power Sources
0378-7753,
136
, pp.
55
65
.
2.
Miesse
,
C. M.
,
Jung
,
W. S.
,
Jeong
,
K. J.
,
Lee
,
J. K.
,
Lee
,
J.
,
Han
,
J.
,
Yoon
,
S. P.
,
Lim
,
T. H.
, and
Hong
,
S. A.
, 2006, “
Direct Formic Acid Fuel Cell Portable Power System for the Operation of a Laptop Computer
,”
J. Power Sources
0378-7753,
162
, pp.
532
540
.
3.
Wilhelm
,
A. N.
,
Surgenor
,
B. W.
, and
Pharoah
,
J. G.
, 2006, “
Design and Evaluation of a Micro-Fuel-Cell-Based Power System for a Mobile Robot
,”
IEEE/ASME Trans. Mechatron.
1083-4435,
11
, pp.
471
476
.
4.
O’Hayre
,
R.
,
Cha
,
S. W.
,
Colella
,
W.
, and
Prinz
,
F. B.
, 2006,
Fuel Cell Fundamentals
,
Wiley
,
New York
, Chap. 8.
5.
Argyropoulos
,
P.
,
Scott
,
K.
, and
Taama
,
W. M.
, 2000, “
Dynamic Response of the Direct Methanol Fuel Cell Under Variable Load Conditions
,”
J. Power Sources
0378-7753,
87
, pp.
153
161
.
6.
Larminie
,
J.
, and
Dicks
,
A.
, 2000,
Fuel Cell Systems Explained
,
Wiley
,
New York
, p.
142
.
7.
Vengatesan
,
S.
,
Kim
,
H. J.
,
Cho
,
E. A.
,
Jeong
,
S. U.
,
Ha
,
H. Y.
,
Oh
,
I. H.
,
Hong
,
S. A.
, and
Lim
,
T. H.
, 2006, “
Operation of a Proton Exchange Membrane Fuel Cell Under Non-Humidified Conditions Using Thin Cast Nafion Membranes With Different Gas-Diffusion Media
,”
J. Power Sources
0378-7753,
156
, pp.
294
299
.
8.
Neyerlin
,
K. C.
,
Gasteiger
,
H. A.
,
Mittelsteadt
,
C. K.
,
Jorne
,
J.
, and
Gu
,
W.
, 2005, “
Effect of Relative Humidity on Oxygen Reduction Kinetics in a PEMFC
,”
J. Electrochem. Soc.
0013-4651,
152
(
6
), pp.
A1073
A1080
.
9.
Doyle
,
M.
, and
Rajendran
,
G.
, 2003,
Handbook of Fuel Cells
,
Wiley
,
Chichester, UK
, Vol.
3
, pp.
351
395
.
10.
Motupally
,
S.
,
Becker
,
A. J.
, and
Weidner
,
J. W.
, 2000, “
Diffusion of Water in Nafion 115 Membranes
,”
J. Electrochem. Soc.
0013-4651,
147
(
9
), pp.
3171
3177
.
11.
Ju
,
H.
,
Meng
,
H.
, and
Wang
,
C. -Y.
, 2005, “
A Single-Phase, Non-Isothermal Model for PEM Fuel Cells
,”
Int. J. Heat Mass Transfer
0017-9310,
48
, pp.
1303
1315
.
12.
Parthasarathy
,
A.
,
Srinivasan
,
S.
,
Appleby
,
A. J.
, and
Martin
,
C. R.
, 1992, “
Temperature Dependence of the Electrode Kinetics of Oxygen Reduction at the Platinum/Nafion Interface—A Microelectrode Investigation
,”
J. Electrochem. Soc.
0013-4651,
139
(
9
), pp.
2530
2537
.
13.
Kim
,
S. J.
,
Lee
,
J.
,
Kong
,
K. Y.
,
Jung
,
C. R.
,
Min
,
I. -G.
,
Lee
,
S. -Y.
,
Kim
,
H. -J.
,
Nam
,
S. W.
, and
Lim
,
T. -H.
, 2007, “
Hydrogen Generation System Using Sodium Borohydride for Operation of a 400 W-Scale Polymer Electrolyte Fuel Cell Stack
,”
J. Power Sources
0378-7753,
170
, pp.
412
418
.
14.
Knights
,
S. D.
,
Colbow
,
K. M.
,
St-Pierre
,
J.
, and
Wilkinson
,
D. P.
, 2004, “
Aging Mechanisms and Lifetime of PEFC and DMFC
,”
J. Power Sources
0378-7753,
127
, pp.
127
134
.
You do not currently have access to this content.