Skip Nav Destination
Close Modal
Update search
Filter
- Title
- Author
- Author Affiliations
- Full Text
- Abstract
- Keyword
- DOI
- ISBN
- ISBN-10
- ISSN
- EISSN
- Issue
- Journal Volume Number
- References
- Conference Volume Title
- Paper No
Filter
- Title
- Author
- Author Affiliations
- Full Text
- Abstract
- Keyword
- DOI
- ISBN
- ISBN-10
- ISSN
- EISSN
- Issue
- Journal Volume Number
- References
- Conference Volume Title
- Paper No
Filter
- Title
- Author
- Author Affiliations
- Full Text
- Abstract
- Keyword
- DOI
- ISBN
- ISBN-10
- ISSN
- EISSN
- Issue
- Journal Volume Number
- References
- Conference Volume Title
- Paper No
Filter
- Title
- Author
- Author Affiliations
- Full Text
- Abstract
- Keyword
- DOI
- ISBN
- ISBN-10
- ISSN
- EISSN
- Issue
- Journal Volume Number
- References
- Conference Volume Title
- Paper No
Filter
- Title
- Author
- Author Affiliations
- Full Text
- Abstract
- Keyword
- DOI
- ISBN
- ISBN-10
- ISSN
- EISSN
- Issue
- Journal Volume Number
- References
- Conference Volume Title
- Paper No
Filter
- Title
- Author
- Author Affiliations
- Full Text
- Abstract
- Keyword
- DOI
- ISBN
- ISBN-10
- ISSN
- EISSN
- Issue
- Journal Volume Number
- References
- Conference Volume Title
- Paper No
NARROW
Format
Article Type
Subject Area
Topics
Date
Availability
1-3 of 3
Keywords: materials testing
Close
Follow your search
Access your saved searches in your account
Would you like to receive an alert when new items match your search?
Sort by
Journal Articles
Rebecca L. Austman, Cheryl E. Quenneville, Brendon J. B. Beaton, Graham J. W. King, Karen D. Gordon, Cynthia E. Dunning
Journal:
Journal of Biomechanical Engineering
Article Type: Technical Briefs
J Biomech Eng. April 2008, 130(2): 024502.
Published Online: March 28, 2008
... was cemented into the canal by an experienced upper extremity orthopaedic surgeon. Six loads ( 5 – 30 N ) were applied sequentially to the lateral surface of the prosthetic head using a materials testing machine. Testing was repeated after breaking the stem-cement bond, and after removing and reinserting...
Journal Articles
Journal:
Journal of Biomechanical Engineering
Article Type: Technical Briefs
J Biomech Eng. December 2007, 129(6): 913–918.
Published Online: April 19, 2007
...Tao Cheng; Rong Z. Gan, Ph.D. Measurement on mechanical properties of the stapedial tendon in human middle ear has not been reported in the literature. In this paper, we used the material testing system to conduct uniaxial tensile, stress relaxation, and failure tests on stapedial tendon specimens...
Journal Articles
Journal:
Journal of Biomechanical Engineering
Article Type: Technical Papers
J Biomech Eng. December 2003, 125(6): 887–892.
Published Online: January 9, 2004
... device has two clamps. The femoral clamp sits on a pinion gear that is driven by a rack attached to a materials testing system. A 100 N load cell in series with the rack gives force feedback. The tibial clamp is attached to a rotatory potentiometer. The system allows the knee joint multiple degrees...