The human humerus is the third largest longbone and experiences 2–3% of all fractures. Yet, almost no data exist on its intact biomechanical properties, thus preventing researchers from obtaining a full understanding of humerus behavior during injury and after being repaired with fracture plates and nails. The aim of this experimental study was to compare the biomechanical stiffness and strength of “gold standard” fresh-frozen humeri to a variety of humerus models. A series of five types of intact whole humeri were obtained: human fresh-frozen (n = 19); human embalmed (n = 18); human dried (n = 15); artificial “normal” (n = 12); and artificial “osteoporotic” (n = 12). Humeri were tested under “real world” clinical loading modes for shear stiffness, torsional stiffness, cantilever bending stiffness, and cantilever bending strength. After removing geometric effects, fresh-frozen results were 585.8 ± 181.5 N/mm2 (normalized shear stiffness); 3.1 ± 1.1 N/(mm2 deg) (normalized torsional stiffness); 850.8 ± 347.9 N/mm2 (normalized cantilever stiffness); and 8.3 ± 2.7 N/mm2 (normalized cantilever strength). Compared to fresh-frozen values, statistical equivalence (p ≥ 0.05) was obtained for all four test modes (embalmed humeri), 1 of 4 test modes (dried humeri), 1 of 4 test modes (artificial “normal” humeri), and 1 of 4 test modes (artificial “osteoporotic” humeri). Age and bone mineral density versus experimental results had Pearson linear correlations ranging from R = −0.57 to 0.80. About 77% of human humeri failed via a transverse or oblique distal shaft fracture, whilst 88% of artificial humeri failed with a mixed transverse + oblique fracture. To date, this is the most comprehensive study on the biomechanics of intact human and artificial humeri and can assist researchers to choose an alternate humerus model that can substitute for fresh-frozen humeri.

References

1.
Pyati
,
P. S.
,
2006
, “
Fractures of the Humeral Shaft
,”
Handbook of Fractures
,
J. A.
Elstrom
,
W. W.
Virkus
, and
A. M.
Pankovich
, eds.,
McGraw-Hill
,
New York
, pp.
100
112
.
2.
Baumgaertner
,
M.
, and
Tornetta
P.
III
, eds.,
2005
,
Orthopaedic Knowledge Update: Trauma
, American Academy of Orthopaedic Surgeons,
Rosemont, Ill
.
3.
Marsh
,
J. L.
,
Slongo
,
T. F.
,
Agel
,
J.
,
Broderick
,
J. S.
,
Creevey
,
W.
,
DeCoster
,
T. A.
,
Prokuski
,
L.
,
Sirkin
,
M. S.
,
Ziran
,
B.
,
Henley
,
B.
, and
Audigé
,
L.
,
2007
, “
Fracture and Dislocation Classification Compendium—2007: Orthopaedic Trauma Association Classification, Database and Outcomes Committee
,”
J. Orthop. Trauma
,
21
(
10 Suppl
), pp.
S1
S133
.10.1097/00005131-200711101-00001
4.
Infante
,
A. F.
, and
Lindvall
,
E. M.
,
2008
, “
Fractures of the Humeral Shaft
,”
Trauma: Core Knowledge in Orthopaedics
,
R.
Sanders
, ed.,
Mosby-Elsevier
,
Philadelphia, PA
, pp.
79
88
.
5.
Sarmiento
,
A.
,
Horowitch
,
A.
,
Aboulabia
,
A.
, and
Vangsness
,
C. T.
, Jr.
,
1990
, “
Functional Bracing for Comminuted Extra-Articular Fractures of the Distal-Third of the Humerus
,”
J. Bone Jt. Surg. Br.
,
72
(
2
), pp.
283
287
.
6.
Sarmiento
,
A.
,
Zagorski
,
J. B.
,
Zych
,
G. A.
,
Latta
,
L. L.
, and
Capps
,
C. A.
,
2000
, “
Functional Bracing for the Treatment of Fractures of the Humeral Diaphysis
,”
J. Bone Jt. Surg. Am.
,
82
(
4
), pp.
478
486
.10.1302/0301-620X.82B7.11561
7.
Dalton
,
J. E.
,
Salkeld
,
S. L.
,
Satterwhite
,
Y. E.
, and
Cook
,
S. D.
,
1993
, “
A Biomechanical Comparison of Intramedullary Nailing Systems for the Humerus
,”
J. Orthop. Trauma
,
7
(
4
), pp.
367
374
.10.1097/00005131-199308000-00014
8.
Damron
,
T. A.
,
Rock
,
M. G.
,
Choudhury
,
S. N.
,
Grabowski
,
J. J.
, and
An
,
K. N.
,
1999
, “
Biomechanical Analysis of Prophylactic Fixation for Middle Third Humeral Impending Pathologic Fractures
,”
Clin. Orthop. Relat. Res.
,
363
, pp.
240
248
.10.1097/00003086-199906000-00031
9.
Lin
,
J.
,
Inoue
,
N.
,
Valdevit
,
A.
,
Hang
,
Y. S.
,
Hou
,
S. M.
, and
Chao
,
E. Y. S.
,
1998
, “
Biomechanical Comparison of Antegrade and Retrograde Nailing of Humeral Shaft Fracture
,”
Clin. Orthop. Relat. Res.
,
351
, pp.
203
213
.10.1097/00003086-199806000-00025
10.
Schopfer
,
A.
,
Hearn
,
T. C.
,
Malisano
,
L.
,
Powell
,
J. N.
, and
Kellam
,
J. F.
,
1994
, “
Comparison of Torsional Strength of Humeral Intramedullary Nailing: A Cadaveric Study
,”
J. Orthop. Trauma
,
8
(
5
), pp.
414
421
.10.1097/00005131-199410000-00008
11.
Henley
,
M. B.
,
Monroe
,
M.
, and
Tencer
,
A. F.
,
1991
, “
Biomechanical Comparison of Methods of Fixation of a Midshaft Osteotomy of the Humerus
,”
J. Orthop. Trauma
,
5
(
1
), pp.
14
20
.10.1097/00005131-199103000-00003
12.
Füchtmeier
,
B.
,
May
,
R.
,
Hente
,
R.
,
Maghsudi
,
M.
,
Völk
,
M.
,
Hammer
,
J.
,
Nerlich
,
M.
, and
Prantl
,
L.
,
2007
, “
Proximal Humerus Fractures: A Comparative Biomechanical Analysis of Intra and Extramedullary Implants
,”
Arch. Orthop. Trauma Surg.
,
127
(
6
), pp.
441
447
.10.1007/s00402-007-0319-6
13.
Chudik
,
S. C.
,
Weinhold
,
P.
, and
Dahners
,
L. E.
,
2003
, “
Fixed-Angle Plate Fixation in Simulated Fractures of the Proximal Humerus: A Biomechanical Study of a New Device
,”
J. Shoulder Elbow Surg.
,
12
(
6
), pp.
578
588
.10.1016/S1058-2746(03)00217-9
14.
Chin
,
H. C.
,
Frassica
,
F. J.
,
Hein
,
T. J.
,
Shives
,
T. C.
,
Pritchard
,
D. J.
,
Sim
,
F. H.
, and
Chao
,
E. Y.
,
1989
, “
Metastatic Diaphyseal Fractures of the Shaft of the Humerus. The Structural Strength Evaluation of a New Method of Treatment With a Segmental Defect Prosthesis
,”
Clin. Orthop. Relat. Res.
,
248
, pp.
231
239
.
15.
Sawbones, last accessed Jan. 1, 2014 Available at: http://www.sawbones.com/catalog/pdf/us_catalog.pdf
16.
Al-Jahwari
,
A.
,
Schemitsch
,
E. H.
,
Wunder
,
J. S.
,
Ferguson
,
P. C.
, and
Zdero
,
R.
,
2012
, “
The Biomechanical Effect of Torsion on Humeral Shaft Repair Techniques for Completed Pathological Fractures
,”
ASME J. Biomech. Eng.
,
134
(
2
), pp.
0245011
0245017
.10.1115/1.4005696
17.
Lescheid
,
J.
,
Zdero
,
R.
,
Shah
,
S.
,
Kuzyk
,
P. R. T.
, and
Schemitsch
,
E. H.
,
2010
, “
The Biomechanics of Locked Plating for Repairing Proximal Humerus Fractures With or Without Medial Cortical Support
,”
J. Trauma
,
69
(
5
), pp.
1235
1242
[Epub 2010 Jan 28].10.1097/TA.0b013e3181beed96
18.
Ahmad
,
M.
,
Nanda
,
R.
,
Bajwa
,
A. S.
,
Candal-Couto
,
J.
,
Green
,
S.
, and
Hui
,
A. C.
,
2007
, “
Biomechanical Testing of the Locking Compression Plate: When Does the Distance Between Bone and Implant Significantly Reduce Construct Stability?
Injury
,
38
(
3
), pp.
358
364
.10.1016/j.injury.2006.08.058
19.
Virkus
,
W. V.
,
Goldberg
,
S. H.
, and
Lorenz
,
E. P.
,
2008
, “
A Comparison of Compressive Force Generation by Plating and Intramedullary Nailing Techniques in a Transverse Diaphyseal Humerus Fracture Model
,”
J. Trauma
,
65
(
1
), pp.
103
108
.10.1097/TA.0b013e3181568ce7
20.
Papini
,
M.
,
Zdero
,
R.
,
Schemitsch
,
E. H.
, and
Zalzal
,
P.
,
2007
, “
The Biomechanics of Human Femurs in Axial and Torsional Loading: Comparison of Finite Element Analysis, Human Cadaveric Femurs, and Synthetic Femurs
,”
ASME J. Biomech. Eng.
,
129
(
1
), pp.
12
19
.10.1115/1.2401178
21.
Zdero
,
R.
,
Elfallah
,
K.
,
Olsen
,
M.
, and
Schemitsch
,
E. H.
,
2009
, “
Cortical Screw Purchase in Synthetic and Human Femurs
,”
ASME J. Biomech. Eng.
,
131
(
9
), p.
094503
.10.1115/1.3194755
22.
Zdero
,
R.
,
Olsen
,
M.
,
Bougherara
,
H.
, and
Schemitsch
,
E. H.
,
2008
, “
Cancellous Bone Screw Purchase: A Comparison of Synthetic Femurs, Human Femurs, and Finite Element Analysis
,”
Proc. Inst. Mech. Eng., Part H
,
222
(
8
), pp.
1175
1183
.10.1243/09544119JEIM409
23.
Dunlap
,
J. T.
,
Chong
,
A. C.
,
Lucas
,
G. L.
, and
Cooke
,
F. W.
,
2008
, “
Structural Properties of a Novel Design of Composite Analogue Humeri Models
,”
Ann. Biomed. Eng.
,
36
(
11
), pp.
1922
1926
[Epub 2008 Sep 17].10.1007/s10439-008-9568-y
24.
Lewiecki
,
E. M.
, and
Borges
,
J. L. C.
,
2006
, “
Bone Density Testing in Clinical Practice
,”
Arq. Bras. Endocrinol. Metabol.
,
50
(
4
), pp.
586
595
.
25.
Pettersson
,
U.
,
Nordström
,
P.
, and
Lorentzon
,
R.
,
1999
, “
A Comparison of Bone Mineral Density and Muscle Strength in Young Male Adults With Different Exercise Level
,”
Calcif. Tissue Int.
,
64
(
6
), pp.
490
498
.10.1007/s002239900639
26.
Lochmuller
,
E. M.
,
Krefting
,
N.
,
Burklein
,
D.
, and
Eckstein
,
F.
,
2001
, “
Effect of Fixation, Soft–Tissues, and Scan Projection on Bone Mineral Measurements With Dual X-Ray Absorptiometry (DXA)
,”
Calcif. Tissue Int.
,
68
(
3
), pp.
140
145
.
27.
Koval
,
K. J.
,
Blair
,
B.
,
Takei
,
R.
,
Kummer
,
F. J.
, and
Zuckerman
,
J. D.
,
1996
, “
Surgical Neck Fractures of the Proximal Humerus: A Laboratory Evaluation of Ten Fixation Techniques
,”
J. Trauma
,
40
(
5
), pp.
778
783
.10.1097/00005373-199605000-00017
28.
Jiang
,
C.
,
Zhu
,
Y.
,
Wang
,
M.
, and
Rong
,
G.
,
2007
, “
Biomechanical Comparison of Different Pin Configurations During Percutaneous Pinning for the Treatment of Proximal Humeral Fractures
,”
J. Shoulder Elbow Surg.
,
16
(
2
), pp.
235
239
[Epub 2007 Jan 31].10.1016/j.jse.2006.05.011
29.
Sabick
,
M. B.
,
Torry
,
M. R.
,
Kim
,
Y.-K.
, and
Hawkins
,
R. J.
,
2004
, “
Humeral Torque in Professional Baseball Pitchers
,”
Am. J. Sports Med.
,
32
(
4
), pp.
892
898
.10.1177/0363546503259354
30.
Feltner
,
M. E.
, and
Dapena
,
J.
,
1986
, “
Dynamics of the Shoulder and Elbow Joints of the Throwing Arm During a Baseball Pitch
,”
Int. J. Sport Biomech.
,
2
(
4
), pp.
235
259
.
31.
Fleisig
,
G. S.
,
Andrews
,
J. R.
,
Dillman
,
C. J.
, and
Escamilla
,
R. F.
,
1995
, “
Kinetics of Baseball Pitching With Implications About Injury Mechanisms
,”
Am. J. Sports Med.
,
23
(
2
), pp.
233
239
.10.1177/036354659502300218
32.
Edwards
,
S. L.
,
Wilson
,
N. A.
,
Zhang
,
L. Q.
,
Flores
,
S.
, and
Merk
,
B. R.
,
2006
, “
Two-Part Surgical Neck Fractures of the Proximal Part of the Humerus. A Biomechanical Evaluation of Two Fixation Techniques
,”
J. Bone Jt. Surg. Am.
,
88
(
10
), pp.
2258
2264
.10.2106/JBJS.E.00757
33.
Kitson
,
J.
,
Booth
,
G.
, and
Day
,
R.
,
2007
, “
A Biomechanical Comparison of Locking Plate and Locking Nail Implants Used for Fractures of the Proximal Humerus
,”
J. Shoulder Elbow Surg.
,
16
(
3
), pp.
362
366
[Epub 2007 Mar 21].10.1016/j.jse.2006.01.019
34.
Lever
,
J. P.
,
Zdero
,
R.
,
Nousiainen
,
M. T.
,
Waddell
,
J. P.
, and
Schemitsch
,
E. H.
,
2010
, “
The Biomechanical Analysis of Three Plating Fixation Systems for Periprosthetic Femoral Fracture Near the Tip of a Total Hip Arthroplasty
,”
J. Orthop. Surg. Res.
, 5;45.10.1186/1749-799X-5-45
35.
Norton
,
R. L.
,
1996
,
Machine Design: An Integrated Approach
,
Prentice-Hall, Upper Saddle River
,
NJ
.
36.
Edmonston
,
S. J.
,
Singer
,
K. P.
,
Day
,
R. E.
,
Breidahl
,
P. D.
, and
Price
,
R. I.
,
1994
, “
In vitro Relationships Between Vertebral Body Density, Size, and Compressive Strength in the Elderly Thoracolumbar Spine
,”
Clin. Biomech.
,
9
(
3
), pp.
180
186
.10.1016/0268-0033(94)90019-1
37.
Sedlin
,
E. D.
, and
Hirsch
,
C.
,
1966
, “
Factors Affecting the Determination of the Physical Properties of Femoral Cortical Bone
,”
Acta Orthop. Scand.
,
37
(
1
), pp.
29
48
.10.3109/17453676608989401
38.
McElhaney
,
J.
,
Fogle
,
J.
,
Byars
,
E.
, and
Weaver
,
G.
,
1964
, “
Effect of Embalming on the Mechanical Properties of Beef Bone
,”
J. Appl. Physiol.
,
19
, pp.
1234
1236
.
39.
Evans
,
F. G.
,
1957
,
Stress and Strain in Bones
,
C. C.
Thomas
, ed.,
Springfield, Ill
.
40.
Calabrisi
,
P.
, and
Smith
,
F. C.
,
1951
, “
The Effect of Embalming on the Compressive Strength of a Few Specimens of Compact Bone
,” U.S. Naval Medical Research Institute, Project No. NM 001056.02.
41.
Ekholm
,
R.
,
Adami
,
J.
,
Tidermark
,
J.
,
Hansson
,
K.
,
Törnkvist
,
H.
, and
Ponzer
,
S.
,
2006
, “
Fractures of the Shaft of the Humerus. An Epidemiological Study of 401 Fractures
,”
J. Bone Jt. Surg. Br.
,
88
(
11
), pp.
1469
1473
.10.1302/0301-620X.88B11.17634
42.
MacAvelia
,
T.
,
Salahi
,
M.
,
Olsen
,
M.
,
Crookshank
,
M.
,
Schemitsch
,
E. H.
,
Ghasempoor
,
A.
,
Janabi-Sharifi
,
F.
, and
Zdero
,
R.
,
2012
, “
Biomechanical Measurements of Surgical Drilling Force and Torque in Human Versus Artificial Femurs
,”
ASME J. Biomech. Eng.
,
134
(
12
), p.
124503
.10.1115/1.4007953
43.
Olsen
,
M.
,
Sellan
,
M.
,
Zdero
,
R.
,
Waddell
,
J. P.
, and
Schemitsch
,
E. H.
,
2011
, “
A Biomechanical Comparison of Epiphyseal Versus Metaphyseal Fixed Bone–Conserving Hip Arthroplasty
,”
J. Bone Jt. Surg. Am.
,
93
(
Suppl 2
), pp.
122
127
.10.2106/JBJS.J.01709
44.
Crookshank
,
M.
,
Coquim
,
J.
,
Olsen
,
M.
,
Schemitsch
,
E. H.
,
Bougherara
,
H.
, and
Zdero
,
R.
,
2012
, “
Biomechanical Measurements of Axial Crush Injury to the Distal Condyles of Human and Synthetic Femurs
,”
Proc. Inst. Mech. Eng., Part H
,
226
(
4
), pp.
320
329
.10.1177/0954411912438038
45.
Mantila Roosa
,
S. M.
,
Hurd
,
A. L.
,
Xu
,
H.
,
Fuchs
,
R. K.
, and
Warden
,
S. J.
,
2012
, “
Age-Related Changes in Proximal Humerus Bone Health in Healthy, White Males
,”
Osteoporosis Int.
,
23
(
12
), pp.
2775
2783
.10.1007/s00198-012-1893-1
46.
Shah
,
S.
,
Kim
,
S. Y. R.
,
Dubov
,
A.
,
Schemitsch
,
E. H.
,
Bougherara
,
H.
, and
Zdero
,
R.
,
2011
, “
The Biomechanics of Plate Fixation of Periprosthetic Femoral Fractures Near the Tip of a Total Hip Implant: Cables, Screws, or Both?
,”
Proc. Inst. Mech. Eng., Part H
,
225
(
9
), pp.
845
856
[Epub 2011 June 30].10.1177/0954411911413060
47.
Dubov
,
A.
,
Kim
,
S. Y. R.
,
Shah
,
S.
,
Schemitsch
,
E. H.
,
Zdero
,
R.
, and
Bougherara
,
H.
,
2011
, “
The Biomechanics of Plate Repair of Periprosthetic Femur Fractures Near the Tip of a Total Hip Implant: The Effect of Cable-Screw Position
,”
Proc. Inst. Mech. Eng., Part H
,
225
(
9
), pp.
857
865
[Epub 2011 June 16].10.1177/0954411911410642
48.
Sammarco
,
G. J.
,
Burstein
,
A. H.
,
Davis
,
W. L.
, and
Frankel
,
V. H.
,
1971
, “
The Biomechanics of Torsional Fractures: The Effect of Loading on Ultimate Properties
,”
J. Biomech.
,
4
(
2
), pp.
113
117
.10.1016/0021-9290(71)90021-2
49.
Zdero
,
R.
,
McConnell
,
A. J.
,
Peskun
,
C.
,
Syed
,
K. A.
, and
Schemitsch
,
E. H.
,
2011
, “
Biomechanical Measurements of Torsion-Tension Coupling in Human Cadaveric Femurs
,”
J. Biomech. Eng.
,
133
(
1
), p.
014501
.
50.
Hessmann
,
M. H.
,
Hansen
,
W. S.
,
Krummenauer
,
F.
,
Pol
,
T. F.
, and
Rommens
,
P.
,
2005
, “
Locked Plate Fixation and Intramedullary Nailing for Proximal Humerus Fractures: A Biomechanical Evaluation
,”
J. Trauma
,
58
(
6
), pp.
1194
1201
.10.1097/01.TA.0000170400.68994.AB
51.
Kralinger
,
F.
,
Gschwentner
,
M.
,
Wambacher
,
M.
,
Smekal
,
V.
, and
Haid
,
C.
,
2008
, “
Proximal Humeral Fractures: What is Semi-Rigid? Biomechanical Properties of Semi-Rigid Implants, A Biomechanical Cadaver Based Evaluation
,”
Arch. Orthop. Trauma Surg.
,
128
(
2
), pp.
205
210
[Epub 2007 Nov 27].10.1007/s00402-007-0512-7
52.
Lever
,
J. P.
,
Aksenov
,
S. A.
,
Zdero
,
R.
,
Ahn
,
H.
,
McKee
,
M. D.
, and
Schemitsch
,
E. H.
,
2008
, “
Biomechanical Analysis of Plate Osteosynthesis Systems for Proximal Humerus Fractures
,”
J. Orthop. Trauma
,
22
(
1
), pp.
23
29
.10.1097/BOT.0b013e31815c89ce
53.
Maldonado
,
Z. M.
,
Seebeck
,
J.
,
Heller
,
M. O.
,
Brandt
,
D.
,
Hepp
,
P.
,
Lill
,
H.
, and
Duda
,
G. N.
,
2003
, “
Straining of the Intact and Fractured Proximal Humerus under Physiological-Like Loading
,”
J. Biomech.
,
36
(
12
), pp.
1865
1873
.10.1016/S0021-9290(03)00212-4
54.
Mather
,
B. S.
,
1968
, “
Observations on the Effects of Static and Impact Loading on the Human Femur
,”
J. Biomech.
,
1
(
4
), pp.
331
335
.10.1016/0021-9290(68)90027-4
55.
Zdero
,
R.
,
Gallimore
,
C. H.
,
McConnell
,
A. J.
,
Patel
,
H.
,
Nisenbaum
,
R.
,
Morshed
,
G.
,
Koo
,
H.
,
McKee
,
M. D.
,
Schemitsch
,
E. H.
, and
Bougherara
,
H.
,
2012
, “
A Preliminary Biomechanical Study of Cyclic Preconditioning Effects on Canine Cadaveric Whole Femurs
,”
ASME J. Biomech. Eng.
,
134
(
9
), p.
094502
.10.1115/1.4007249
56.
Cristofolini
,
L.
,
Viceconti
,
M.
,
Cappello
,
A.
, and
Toni
,
A.
,
1996
, “
Mechanical Validation of Whole Bone Composite Femur Models
,”
J. Biomech.
,
29
(
4
), pp.
525
535
.10.1016/0021-9290(95)00084-4
57.
Martens
,
M.
,
van Audekercke
,
R.
,
de Meester
,
P.
, and
Mulier
,
J. C.
,
1986
, “
Mechanical Behaviour of Femoral Bones in Bending Loading
,”
J. Biomech.
,
19
(
6
), pp.
443
454
.10.1016/0021-9290(86)90021-7
58.
Allen
,
M. D.
,
McMillan
,
S. J.
,
Klein
,
C. S.
,
Rice
,
C. L.
, and
Marsh
,
G. D.
,
2012
, “
Differential Age–Related Changes in Bone Geometry Between the Humerus and the Femur in Healthy Men
,”
Aging and Disease
,
3
(
2
), pp.
156
163
.
59.
Forwood
,
M. R.
,
2001
, “
Mechanical Effects on the Skeleton: Are There Clinical Implications?
Osteoporosis Int.
,
12
(
1
), pp.
77
83
.10.1007/s001980170161
60.
Myers
,
E. R.
,
Hecker
,
A. T.
,
Rooks
,
D. S.
,
Hipp
,
J. A.
, and
Hayes
,
W. C.
,
1993
, “
Geometric Variables From DXA of the Radius Predict Forearm Fracture Load in vitro
,”
Calcif. Tissue Int.
,
52
(
3
), pp.
199
204
.10.1007/BF00298718
61.
Foldes
,
J.
,
Parfitt
,
A. M.
,
Shih
,
M. S.
,
Rao
,
D. S.
, and
Kleerekoper
,
M.
,
1991
, “
Structural and Geometric Changes in Iliac Bone: Relationship to Normal Aging and Osteoporosis
,”
J. Bone Miner. Res.
,
6
(
7
), pp.
759
766
.10.1002/jbmr.5650060714
62.
Zdero
,
R.
,
Bougherara
,
H.
,
Dubov
,
A.
,
Shah
,
S.
,
Zalzal
,
P.
,
Mahfud
,
A.
, and
Schemitsch
,
E. H.
,
2010
, “
The Effect of Cortex Thickness on Intact Femur Biomechanics: A Comparison of Finite Element Analysis With Synthetic Femurs
,”
Proc. Inst. Mech. Eng., Part H
,
224
(
7
), pp.
831
840
.10.1243/09544119JEIM702
63.
Ammann
,
P.
, and
Rizzoli
,
R.
,
2003
, “
Bone Strength and Its Determinants
,”
Osteoporosis Int.
,
14
(
S3
), pp.
13
18
.10.1007/s00198-002-1311-1
You do not currently have access to this content.