Low Reynolds number airflow in the pulmonary acinus and aerosol particle kinetics therein are significantly conditioned by the nature of the tidal motion of alveolar duct geometry. At least two components of the ductal structure are known to exhibit stress-strain hysteresis: smooth muscle within the alveolar entrance rings, and surfactant at the air-tissue interface. We hypothesize that the geometric hysteresis of the alveolar duct is largely determined by the interaction of the amount of smooth muscle and connective tissue in ductal rings, septal tissue properties, and surface tension-surface area characteristics of surfactant. To test this hypothesis, we have extended the well-known structural model of the alveolar duct by Wilson and Bachofen (1982, “A Model for Mechanical Structure of the Alveolar Duct,” J. Appl. Physiol. 52(4), pp. 1064–1070) by adding realistic elastic and hysteretic properties of (1) the alveolar entrance ring, (2) septal tissue, and (3) surfactant. With realistic values for tissue and surface properties, we conclude that: (1) there is a significant, and underappreciated, amount of geometric hysteresis in alveolar ductal architecture; and (2) the contribution of smooth muscle and surfactant to geometric hysteresis are of opposite senses, tending toward cancellation. Quantitatively, the geometric hysteresis found experimentally by Miki et al. (1993, “Geometric Hysteresis in Pulmonary Surface-to-Volume Ratio during Tidal Breathing,” J. Appl. Physiol. 75(4), pp. 1630–1636) is consistent with little or no smooth muscle tone in anesthetized rabbits in control conditions, and with substantial smooth muscle activation following methacholine challenge. The observed local hysteretic boundary motion of the acinar duct would result in irreversible acinar flow fields, which might be important mechanistic contributors to aerosol mixing and deposition deep in the lung.
Skip Nav Destination
e-mail: atsuda@hsph.harvard.edu
Article navigation
November 2011
Research Papers
Geometric Hysteresis of Alveolated Ductal Architecture
M. Kojic,
M. Kojic
Molecular and Integrative Physiological Sciences, Harvard School of Public Health, Boston, MA 02115; Research and Development Center for Bioengineering, Kragujevac, Serbia 34000;
The Methodist Hospital Research Institute
, Houston, TX 77030
Search for other works by this author on:
J. P. Butler,
J. P. Butler
Molecular and Integrative Physiological Sciences, Harvard School of Public Health, Boston, MA 02115
Search for other works by this author on:
I. Vlastelica,
I. Vlastelica
Metropolitan University
, Belgrade, Serbia 11000
Search for other works by this author on:
B. Stojanovic,
B. Stojanovic
Faculty of Science,
University of Kragujevac
, Serbia, Kragujevac, Serbia 34000
Search for other works by this author on:
V. Rankovic,
V. Rankovic
Faculty of Economics,
University of Kragujevac
, Serbia, Kragujevac, Serbia 34000
Search for other works by this author on:
A. Tsuda
A. Tsuda
Molecular and Integrative Physiological Sciences, Harvard School of Public Health, Boston, MA 02115
e-mail: atsuda@hsph.harvard.edu
Search for other works by this author on:
M. Kojic
Molecular and Integrative Physiological Sciences, Harvard School of Public Health, Boston, MA 02115; Research and Development Center for Bioengineering, Kragujevac, Serbia 34000;
The Methodist Hospital Research Institute
, Houston, TX 77030
J. P. Butler
Molecular and Integrative Physiological Sciences, Harvard School of Public Health, Boston, MA 02115
I. Vlastelica
Metropolitan University
, Belgrade, Serbia 11000
B. Stojanovic
Faculty of Science,
University of Kragujevac
, Serbia, Kragujevac, Serbia 34000
V. Rankovic
Faculty of Economics,
University of Kragujevac
, Serbia, Kragujevac, Serbia 34000
A. Tsuda
Molecular and Integrative Physiological Sciences, Harvard School of Public Health, Boston, MA 02115
e-mail: atsuda@hsph.harvard.edu
J Biomech Eng. Nov 2011, 133(11): 111005 (11 pages)
Published Online: November 29, 2011
Article history
Received:
September 11, 2011
Accepted:
October 19, 2011
Online:
November 29, 2011
Published:
November 29, 2011
Citation
Kojic, M., Butler, J. P., Vlastelica, I., Stojanovic, B., Rankovic, V., and Tsuda, A. (November 29, 2011). "Geometric Hysteresis of Alveolated Ductal Architecture." ASME. J Biomech Eng. November 2011; 133(11): 111005. https://doi.org/10.1115/1.4005380
Download citation file:
Get Email Alerts
Estimation of Joint Kinetics During Manual Material Handling Using Inertial Motion Capture: A Follow-Up Study
J Biomech Eng (February 2025)
Effect of Compressive Strain Rates on Viscoelasticity and Water Content in Intact Porcine Stomach Wall Tissues
J Biomech Eng (February 2025)
Eyelid Motion Tracking During Blinking Using High-Speed Imaging and Digital Image Correlation
J Biomech Eng (January 2025)
Related Articles
Viscoelastic Behavior of a Lung Alveolar Duct Model
J Biomech Eng (April,2000)
Dynamics of Voluntary Cough Maneuvers: A Theoretical Model
J Biomech Eng (January,2009)
Dynamic Behavior of Lung Surfactant
J Biomech Eng (February,2001)
Targeted Drug Aeroso Deposition Analysis for a Four-Generation Lung Airway Model With Hemispherical Tumors
J Biomech Eng (April,2003)
Related Proceedings Papers
Related Chapters
Clinical issues and experience
Mechanical Blood Trauma in Circulatory-Assist Devices
Health and Safety and Emergency Response
Pipeline Transportation of Carbon Dioxide Containing Impurities
Characterization of Skeletal Muscle Elasticity Using Magnetic Resonance Elastography
Biomedical Applications of Vibration and Acoustics in Imaging and Characterizations