The main reason for the revision of total hip replacements is aseptic loosening, caused by stress shielding and wear particle induced osteolysis. In order to detect an implant loosening early, the osseointegration of endoprosthetic implants must be measured exactly. Currently applied diagnostic methods, such as standard radiographs and clinical symptomatology, often result in an imprecise diagnosis. A novel radiation-free method to improve the diagnostic investigation of implant loosening is presented. The osseointegration of an implant can be identified using mechanical magnetic sensors (oscillators), which impinge on small membranes inside an implant component, e.g., the femoral hip stem. The maximum velocity after impingement of the oscillator depends on the osseointegration of the implant. Excitation of the oscillator is realized by a coil outside the human body. Another external coil is used to detect the velocity of the oscillator. To demonstrate the principle of the novel loosening sensor, an overdimensioned test device was designed to measure simulated loosening phases in the first experimental tests with different material layers. The overdimensioned test device of the loosening sensor showed significant differences in the various phases of fixation. Analysis of the membrane without any material layer in the case of advanced loosening resulted in a 23% higher maximum velocity compared to an attached artificial bone layer. Based on these preliminary results, the sensor system shows potential for the detection of implant loosening. Moreover, the proposed system could be used in experimental applications to determine the quality of bioactive coatings and new implant materials.
Skip Nav Destination
e-mail: catherine.ruther@med.uni-rostock.de
Article navigation
October 2011
Technical Briefs
A Novel Sensor Concept for Optimization of Loosening Diagnostics in Total Hip Replacement
Cathérine Ruther,
Cathérine Ruther
Department of Orthopedics,
e-mail: catherine.ruther@med.uni-rostock.de
University of Rostock
, 18057 Rostock, Germany
Search for other works by this author on:
Hartmut Ewald,
Hartmut Ewald
Institute of General Electrical Engineering,
University of Rostock
, 18057 Rostock, Germany
Search for other works by this author on:
Wolfram Mittelmeier,
Wolfram Mittelmeier
Department of Orthopedics,
University of Rostock
, 18057 Rostock, Germany
Search for other works by this author on:
Andreas Fritsche,
Andreas Fritsche
Department of Orthopedics,
University of Rostock
, 18057 Rostock, Germany
Search for other works by this author on:
Rainer Bader,
Rainer Bader
Department of Orthopedics,
University of Rostock
, 18057 Rostock, Germany
Search for other works by this author on:
Daniel Kluess
Daniel Kluess
Department of Orthopedics,
University of Rostock
, 18057 Rostock, Germany
Search for other works by this author on:
Cathérine Ruther
Department of Orthopedics,
University of Rostock
, 18057 Rostock, Germany
e-mail: catherine.ruther@med.uni-rostock.de
Hartmut Ewald
Institute of General Electrical Engineering,
University of Rostock
, 18057 Rostock, Germany
Wolfram Mittelmeier
Department of Orthopedics,
University of Rostock
, 18057 Rostock, Germany
Andreas Fritsche
Department of Orthopedics,
University of Rostock
, 18057 Rostock, Germany
Rainer Bader
Department of Orthopedics,
University of Rostock
, 18057 Rostock, Germany
Daniel Kluess
Department of Orthopedics,
University of Rostock
, 18057 Rostock, Germany
J Biomech Eng. Oct 2011, 133(10): 104503 (5 pages)
Published Online: November 3, 2011
Article history
Received:
January 3, 2011
Revised:
September 27, 2011
Accepted:
September 27, 2011
Online:
November 3, 2011
Published:
November 3, 2011
Citation
Ruther, C., Ewald, H., Mittelmeier, W., Fritsche, A., Bader, R., and Kluess, D. (November 3, 2011). "A Novel Sensor Concept for Optimization of Loosening Diagnostics in Total Hip Replacement." ASME. J Biomech Eng. October 2011; 133(10): 104503. https://doi.org/10.1115/1.4005222
Download citation file:
Get Email Alerts
Effect of Collagen Fiber Tortuosity Distribution on the Mechanical Response of Arterial Tissues
J Biomech Eng (February 2025)
Related Articles
Characterization of Chitosan Coated Magnetoelastic Materials for Use in Percutaneous Implants
J. Med. Devices (June,2008)
A New Cemented Hip Prosthesis Concept
J. Med. Devices (June,2011)
Design and Validation of a Machine for Reproducible Precision Insertion of Femoral Hip Prostheses for Preclinical Testing
J Biomech Eng (April,2000)
Human Joint Simulation Using LifeMOD Co-Simulation
J. Med. Devices (June,2008)
Related Proceedings Papers
Related Chapters
Computer Aided Oracle Bone Inscriptions Textual Research Based on Ontology
International Conference on Mechanical and Electrical Technology, 3rd, (ICMET-China 2011), Volumes 1–3
Research on Oracle Bone Inscriptions Machine Translation Based on Example and Ontology
International Conference on Advanced Computer Theory and Engineering, 4th (ICACTE 2011)
Application of Non-Linear Elastic Wave Spectroscopy (NEWS) to In Vitro Damage Assessment in Cortical Bone
Biomedical Applications of Vibration and Acoustics in Imaging and Characterizations