Abstract

A detailed three-dimensional finite element model of the face is presented in this paper. Bones, muscles, skin, fat, and superficial muscoloaponeurotic system were reconstructed from magnetic resonance images and modeled according to anatomical, plastic, and reconstructive surgery literature. The finite element mesh, composed of hexahedron elements, was generated through a semi-automatic procedure with an effective compromise between the detailed representation of anatomical parts and the limitation of the computational time. Nonlinear constitutive equations are implemented in the finite element model. The corresponding model parameters were selected according to previous work with mechanical measurements on soft facial tissue, or based on reasonable assumptions. Model assumptions concerning tissue geometry, interactions, mechanical properties, and the boundary conditions were validated through comparison with experiments. The calculated response of facial tissues to gravity loads, to the application of a pressure inside the oral cavity and to the application of an imposed displacement was shown to be in good agreement with the data from corresponding magnetic resonance images and holographic measurements. As a first application, gravimetric soft tissue descent was calculated from the long time action of gravity on the face in the erect position, with tissue aging leading to a loss of stiffness. Aging predictions are compared with the observations from an “aging database” with frontal photos of volunteers at different age ranges (i.e., 20–40 years and 50–70 years).

References

1.
Cutting
,
C.
,
Oliker
,
A.
,
Haring
,
J.
,
Dayan
,
J.
, and
Smith
,
D.
, 2002, “
Use of Three-Dimensional Computer Graphic Animation to Illustrate Cleft Lip and Palate Surgery
,”
Comput. Aided Surg.
,
7
(
6
), pp.
326
331
. 1092-9088
2.
Brett
,
P. N.
,
Fraser
,
C. A.
,
Hennigan
,
M.
,
Griffiths
,
M. V.
, and
Kamel
,
Y.
, 1995, “
Automatic Surgical Tools for Penetrating Flexible Tissues
,”
IEEE Eng. Med. Biol. Mag.
0739-5175,
14
(
3
), pp.
264
270
.
3.
Burdea
,
G. C.
, 1996,
Force and Touch Feedback for Virtual Reality
,
Wiley
,
New York
.
4.
Snedeker
,
J. G.
,
Bajka
,
M.
,
Hug
,
J. M.
,
Szekely
,
G.
, and
Niederer
,
P.
, 2002, “
The Creation of a High-Fidelity Finite Element Model of the Kidney for Use in Trauma Research
,”
J Visual Comp Animat
,
13
(
1
), pp.
53
64
. 1049-8907
5.
Szekely
,
G.
, 2003, “
Surgical Simulators
,”
Minimally Invasive Ther. Allied Technol.
1364-5706,
12
(
1
), pp.
14
18
.
6.
Szekely
,
G.
,
Brechbuhler
,
C.
,
Dual
,
J.
,
Enzler
,
R.
,
Hug
,
J.
,
Hutter
,
R.
,
Ironmonger
,
N.
,
Kauer
,
M.
,
Meier
,
V.
,
Niederer
,
P.
,
Rhomberg
,
A.
,
Schmid
,
P.
,
Schweitzer
,
G.
,
Thaler
,
M.
,
Vuskovic
,
V.
,
Troster
,
G.
,
Haller
,
U.
, and
Bajka
,
M.
, 2000, “
Virtual Reality-Based Simulation of Endoscopic Surgery
,”
Presence-Teleop Virt.
,
9
(
3
), pp.
310
333
. 1054-7460
7.
Terzopoulos
,
D.
, and
Waters
,
K.
, 1990, “
Physically-Based Facial Modeling, Analysis, and Animation
,”
J Visual Comp Animat
,
1
(
2
), pp.
73
80
. 1049-8907
8.
Koch
,
R. M.
,
Gross
,
M. H.
, and
Bosshard
,
A. A.
, 1998, “
Emotion Editing Using Finite Elements
,”
Comput. Graph. Forum
,
17
(
3
), pp.
295
302
. 0167-7055
9.
Rohrle
,
O.
, and
Pullan
,
A. J.
, 2007, “
Three-Dimensional Finite Element Modelling of Muscle Forces During Mastication
,”
J. Biomech.
0021-9290,
40
(
15
), pp.
3363
3372
.
10.
Sifakis
,
E.
,
Selle
,
A.
,
Robinson-Mosher
,
A.
, and
Fedkiw
,
R.
, 2006, “
Simulating Speech With a Physics-Based Facial Muscle Model
,”
ACM SIGGRAPH/Eurographics Symposium on Computer Animation
, pp.
261
270
.
11.
Groleau
,
J.
,
Chabanas
,
M.
,
Marecaux
,
C.
,
Payrard
,
N.
,
Segaud
,
B.
,
Rocchette
,
M.
,
Perrier
,
P.
, and
Payan
,
Y.
, 2007, “
A Biomechanical Model of the Face Including Muscles for the Prediction of Deformations During Speech Production
,”
Proceedings of the 5th International Workshop on Models and Analysis of Vocal Emissions for Biomedical Applications
, pp.
173
176
.
12.
Gladilin
,
E.
,
Zachow
,
S.
,
Deuflhard
,
P.
, and
Hege
,
H. C.
, 2004, “
Anatomy- and Physics-Based Facial Animation for Craniofacial Surgery Simulations
,”
Med. Biol. Eng. Comput.
0140-0118,
42
(
2
), pp.
167
170
.
13.
Mollemans
,
W.
,
Schutyser
,
F.
,
Nadjmi
,
N.
,
Maes
,
F.
, and
Suetens
,
P.
, 2007, “
Predicting Soft Tissue Deformations for a Maxillofacial Surgery Planning System: From Computational Strategies to a Complete Clinical Validation
,”
Med. Image Anal.
,
11
(
3
), pp.
282
301
. 1361-8415
14.
Luboz
,
V.
,
Chabanas
,
M.
,
Swider
,
P.
, and
Payan
,
Y.
, 2005, “
Orbital and Maxillofacial Computer Aided Surgery: Patient-Specific Finite Element Models to Predict Surgical Outcomes
,”
Comput. Methods Biomech. Biomed. Eng.
,
8
(
4
), pp.
259
265
. 1025-5842
15.
Kovacs
,
L.
,
Zimmermann
,
A.
,
Wawrzyn
,
H.
,
Schwenzer
,
K.
,
Seitz
,
H.
,
Tille
,
C.
,
Papadopulos
,
N. A.
,
Sader
,
R.
,
Zeilhofer
,
H. F.
, and
Biemer
,
E.
, 2005, “
Computer Aided Surgical Reconstruction After Complex Facial Burns Injuries-Opportunities and Limitations
,”
Burns
,
31
(
1
), pp.
85
91
. 0305-4179
16.
Keeve
,
E.
,
Girod
,
S.
,
Kikinis
,
R.
, and
Girod
,
B.
, 1998, “
Deformable Modeling of Facial Tissue for Craniofacial Surgery Simulation
,”
Comput. Aided Surg.
,
3
(
5
), pp.
228
238
. 1092-9088
17.
Chabanas
,
M.
,
Luboz
,
V.
, and
Payan
,
Y.
, 2003, “
Patient Specific Finite Element Model of the Face Soft Tissues for Computer-Assisted Maxillofacial Surgery
,”
Med. Image Anal.
,
7
(
2
), pp.
131
151
. 1361-8415
18.
Zachow
,
S.
,
Gladilin
,
E.
,
Hege
,
H. C.
, and
Deuflhard
,
P.
, 2002, “
Towards Patient Specific, Anatomy Based Simulation of Facial Mimics for Surgical Nerve Rehabilitation
,”
CARS 2002: Computer Assisted Radiology and Surgery
, Paris, France, pp.
3
6
.
19.
Gerard
,
J. M.
,
Ohayon
,
J.
,
Luboz
,
V.
,
Perrier
,
P.
, and
Payan
,
Y.
, 2005, “
Non-Linear Elastic Properties of the Lingual and Facial Tissues Assessed by Indentation Technique-Application to the Biomechanics of Speech Production
,”
Med. Eng. Phys.
,
27
(
10
), pp.
884
892
. 1350-4533
20.
Chabanas
,
M.
,
Payan
,
Y.
,
Marecaux
,
C.
,
Swider
,
P.
, and
Boutault
,
F.
, 2004, “
Comparison of Linear and Non-Linear Soft Tissue Models With Post-Operative CT Scan in Maxillofacial Surgery
,”
Lect. Notes Comput. Sci.
,
3078
, pp.
19
27
. 0302-9743
21.
Mazza
,
E.
,
Papes
,
O.
,
Rubin
,
M. B.
,
Bodner
,
S. R.
, and
Binur
,
N. S.
, 2007, “
Simulation of the Aging Face
,”
ASME J. Biomech. Eng.
0148-0731,
129
(
4
), pp.
619
623
.
22.
La Trenta
,
G.
, 2004,
Aesthetic Face & Neck Surgery
,
Saunders
,
Philadelphia, PA
.
23.
Rubin
,
M. B.
, and
Bodner
,
S. R.
, 2002, “
A Three-Dimensional Nonlinear Model for Dissipative Response of Soft Tissue
,”
Int. J. Solids Struct.
0020-7683,
39
(
19
), pp.
5081
5099
.
24.
Mazza
,
E.
,
Papes
,
O.
,
Rubin
,
M. B.
,
Bodner
,
S. R.
, and
Binur
,
N. S.
, 2005, “
Nonlinear Elastic-Viscoplastic Constitutive Equations for Aging Facial Tissues
,”
Biomech. Model. Mechanobiol.
,
4
(
2–3
), pp.
178
189
. 1617-7959
25.
Har-Shai
,
Y.
,
Bodner
,
S. R.
,
Egozy-Golan
,
D.
,
Lindenbaum
,
E. S.
,
Ben-Izhak
,
O.
,
Mitz
,
V.
, and
Hirshowitz
,
B.
, 1996, “
Mechanical Properties and Microstructure of the Superficial Musculoaponeurotic System
,”
Plast. Reconstr. Surg.
0032-1052,
98
(
1
), pp.
59
70
.
26.
Duck
,
F. A.
, 1990,
Physical Properties of Tissue: A Comprehensive Reference Book
,
Academic
,
London
.
27.
Pitanguy
,
I.
,
Pamplona
,
D.
,
Weber
,
H. I.
,
Leta
,
F.
,
Salgado
,
F.
, and
Radwanski
,
H. N.
, 1998, “
Numerical Modeling of Facial Aging
,”
Plast. Reconstr. Surg.
,
102
(
1
), pp.
200
204
. 0032-1052
28.
Lee
,
C. F.
,
Chen
,
P. R.
,
Lee
,
W. J.
,
Chen
,
J. H.
, and
Liu
,
T. C.
, 2006, “
Three-Dimensional Reconstruction and Modeling of Middle Ear Biomechanics by High-Resolution Computed Tomography and Finite Element Analysis
,”
Laryngoscope
,
116
(
5
), pp.
711
716
. 0023-852X
29.
Amira User’s Guide and Amira Reference Manual
,” http://www.amiravis.com.
30.
Platzer
,
W.
,
Leonhardt
,
H.
,
Kahle
,
W.
, and
Frotscher
,
M.
, 1992,
Color Atlas and Textbook of Human Anatomy
,
Thieme
,
Stuttgart
, Vols.
1
.
31.
Schèunke
,
M.
,
Schulte
,
E.
, and
Schumacher
,
U.
, 2005,
Prometheus LernAtlas der Anatomie
,
Thieme
,
Stuttgart
.
32.
Wolf-Heidegger
,
G.
, 1990,
Wolf-Heideggers Atlas der Human-Anatomie
,
Karger
,
Basel
.
33.
Ewart
,
C. J.
,
Jaworski
,
N. B.
,
Rekito
,
A. J.
, and
Gamboa
,
M. G.
, 2005, “
Levator Anguli Oris: A Cadaver Study Implicating Its Role in Perioral Rejuvenation
,”
Ann. Plast. Surg.
,
54
(
3
), pp.
260
263
. 0148-7043
34.
Pessa
,
J. E.
,
Zadoo
,
V. P.
,
Adrian
,
E. K.
,
Yuan
,
C. H.
,
Aydelotte
,
J.
, and
Garza
,
J. R.
, 1998, “
Variability of the Midfacial Muscles: Analysis of 50 Hemifacial Cadaver Dissections
,”
Plast. Reconstr. Surg.
,
102
(
6
), pp.
1888
1893
. 0032-1052
35.
de Castro
,
C. C.
, 2000, “
The Changing Role of Platysma in Face Lifting
,”
Plast. Reconstr. Surg.
,
105
(
2
), pp.
764
775
. 0032-1052
36.
Stuzin
,
J. M.
,
Baker
,
T. J.
, and
Gordon
,
H. L.
, 1992, “
The Relationship of the Superficial and Deep Facial Fascias-Relevance to Rhytidectomy and Aging
,”
Plast. Reconstr. Surg.
,
89
(
3
), pp.
441
449
. 0032-1052
37.
Özdemir
,
R.
,
Kilinc
,
H.
,
Unlu
,
R. E.
,
Uysal
,
A. C.
,
Sensoz
,
O.
, and
Baran
,
C. N.
, 2002, “
Anatomicohistologic Study of the Retaining Ligaments of the Face and Use in Face Lift: Retaining Ligament Correction and SMAS Plication
,”
Plast. Reconstr. Surg.
,
110
(
4
), pp.
1134
1147
. 0032-1052
38.
Olsen
,
L.
,
Takimaki
,
R.
, and
Serup
,
J.
, 1995, “
High-Frequency Ultrasound Characterization of Normal Skin. Skin Thickness and Echographic Density of 22 Anatomical Sites
,”
Skin Res. Technol.
,
1
, pp.
74
80
. 0909-752X
39.
Takema
,
Y.
,
Yorimoto
,
Y.
,
Kawai
,
M.
, and
Imokawa
,
G.
, 1994, “
Age-Related-Changes in the Elastic Properties and Thickness of Human Facial Skin
,”
Br. J. Dermatol.
,
131
(
5
), pp.
641
648
. 0007-0963
40.
Tomlin
,
H. R.
,
Wilson
,
H. J.
, and
Osborne
,
J.
, 1968, “
The Thickness and Hardness of Soft Tissues. A Preliminary Clinical Survey
,”
Br. Dent. J.
,
124
(
5
), pp.
223
226
. 0007-0610
41.
Ghassemi
,
A.
,
Prescher
,
A.
,
Riediger
,
D.
, and
Axer
,
H.
, 2003, “
Anatomy of the SMAS Revisited
,”
Aesthetic Plast. Surg.
,
27
(
4
), pp.
258
264
. 0364-216X
42.
Ferreira
,
L. M.
,
Hochman
,
B.
,
Locali
,
R. F.
, and
Rosa-Oliveira
,
L. M. Q.
, 2006, “
A Stratigraphic Approach to the Superficial Musculoaponeurotic System and Its Anatomic Correlation With the Superficial Fascia
,”
Aesthetic Plast. Surg.
,
30
(
5
), pp.
549
552
. 0364-216X
43.
Black
,
J.
, 1998,
Handbook of Biomaterial Properties
,
Chapman and Hall
,
London
.
44.
Louarn
,
C.
,
Buthiau
,
D.
, and
Buis
,
J.
, 2007, “
Structural Aging: The Facial Recurve Concept
,”
Aesthetic Plast. Surg.
,
31
(
3
), pp.
213
218
. 0364-216X
45.
Gosain
,
A.
,
Klein
,
M. H.
,
Sudhakar
,
P. V.
, and
Prost
,
R. W.
, 2005, “
A Volumetric Analysis of Soft-Tissue Changes in the Aging Midface Using High-Resolution MRI: Implications for Facial Rejuvenation
,”
Plast. Reconstr. Surg.
,
115
(
4
), pp.
1143
1152
. 0032-1052
46.
Heintz
,
S.
,
Hirsch
,
S.
,
Thelen
,
A.
, and
Hering
,
P.
, 2007, “
Three-Dimensional Surface Measurement Using Digital Holography With Pulsed Lasers
,”
Advances in Medical Engineering
,
Springer
,
Berlin
, pp.
435
440
.
47.
Hirsch
,
S.
,
Frey
,
S.
,
Thelen
,
A.
,
Ladriere
,
N.
, and
Hering
,
P.
, 2006, “
Facial Topometry Using Pulsed Holography
,”
Proceedings of the 7th International Symposium on Display Holography
, St. Asaph, Wales.
48.
Hirsch
,
S.
, 2007, “
Digital and Analog Hologram Tomography for Medical Applications
,” PhD thesis, Universität Düsseldorf.
49.
Nkengne
,
A.
,
Bertin
,
C.
,
Stamatas
,
G. N.
,
Giron
,
A.
,
Rossi
,
A.
,
Issachar
,
N.
, and
Fertin
,
B.
, 2008, “
Influence of Facial Skin Attributes on the Perceived Age of Caucasian Women
,”
J. Eur. Acad. Dermatol. Venereol
0926-9959,
22
, pp.
982
991
.
50.
Coleman
,
S. R.
, and
Grover
,
R.
, 2006, “
The Anatomy of the Aging Face: Volume Loss and Changes in 3-Dimensional Topography
,”
Aesthetic Surg. J.
,
26
, pp.
S4
S9
. 1090-820X
51.
Albert
,
A. M.
,
Ricanek
,
K.
, and
Patterson
,
E.
, 2007, “
A Review of the Literature on the Aging Adult Skull and Face: Implications for Forensic Science Research and Applications
,”
Forensic Sci. Int.
,
172
(
1
), pp.
1
9
. 0379-0738
52.
Socci
,
L.
,
Pennati
,
G.
,
Gervaso
,
F.
, and
Vena
,
P.
, 2007, “
An Axisymmetric Computational Model of Skin Expansion and Growth
,”
Biomech. Model. Mechanobiol.
,
6
(
3
), pp.
177
188
. 1617-7959
53.
Menzel
,
A.
, 2005, “
Modelling of Anisotropic Growth in Biological Tissues—A New Approach and Computational Aspects
,”
Biomech. Model. Mechanobiol.
,
3
(
3
), pp.
147
171
. 1617-7959
You do not currently have access to this content.