The combination of computational fluid dynamics (CFD) and magnetic resonance imaging (MRI) offers a promising tool that enables the prediction of blood flow patterns in subject-specific cardiovascular models. The influence of the model geometry on the accuracy of the simulation is well recognized. This paper addresses the impact of different boundary conditions on subject-specific simulations of left ventricular (LV) flow. A novel hybrid method for prescribing effective inflow boundary conditions in the mitral valve plane has been developed. The detailed quantitative results highlight the strengths as well as the potential pitfalls of the approach.
Issue Section:
Technical Briefs
1.
Peskin
, C. S.
, and McQueen
, D. M.
, 1980
, “Modelling prosthetic heart valves for numerical analysis of blood flow in the heart
,” J. Comput. Phys.
, 37
, pp. 113
–32
.2.
Chahboune
, B.
, and Crolet
, J. M.
, 1998
, “Numerical simulation of the blood-wall interaction in the human left ventricle
,” Eur. Phys. J.: Appl. Phys.
, 2
, pp. 291
–97
.3.
Peskin
, C. S.
, and McQueen
, D. M.
, 1992
, “Cardiac fluid-dynamics
,” Crit. Rev. Biomed. Eng.
, 20
, pp. 451
–59
.4.
Lemmon
, J. D.
, and Yoganathan
, A. P.
, 2000
, “Computational modelling of left heart diastolic function: examination of ventricular dysfunction
,” ASME J. Biomech. Eng.
, 122
, pp. 297
–303
.5.
Vierendeels
, J. A.
, Riemslagh
, K.
, Dick
, E.
, and Verdonck
, P. R.
, 2000
, “Computer simulation of intraventricular flow and pressure gradients during diastole
,” ASME J. Biomech. Eng.
, 122
, pp. 667
–674
.6.
Taylor
, T. W.
, and Yamaguchi
, T.
, 1995
, “Realistic three-dimensional left ventricular ejection determined from computational fluid dynamics
,” Med. Eng. Phys.
, 17
, pp. 602
–608
.7.
Jones T. N., and Metaxas D. N., 1998, “Patient-specific analysis of left ventricular blood flow,” Medical Image Computing and Computer-Assisted Intervention-MICCAI’98, pp. 156–166.
8.
Saber
, N. R.
, Gosman
, A. D.
, Wood
, N. B.
, Kilner
, P. J.
, Charrier
, C.
, and Firmin
, D. N.
, 2001
, “Computational flow modelling of the left ventricle based on in vivo MRI data—initial experience
,” Ann. Biomed. Eng.
, 29
, pp. 275
–283
.9.
Saber
, N. R.
, Wood
, N. B.
, Gosman
, A. D.
, Yang
, G. Z.
, Merrifield
, R. D.
, Gatehouse
, P. D.
, Charrier
, C. L.
, and Firmin
, D. N.
, 2003
, “Progress towards parient-specific computational modelling of the left heart via combination of MRI with CFD
,” Ann. Biomed. Eng.
31
, pp. 42
–52
.10.
Long
, Q.
, Xu
, X. Y.
, Collins
, M. W.
, Bourne
, M.
, and Griffith
, T. M.
, 1998
, “Magnetic resonance image processing and structured grid generation of a human abdominal bifurcation
,” Comput. Methods Programs Biomed.
, 56
, pp. 249
–259
.11.
Kilner
, P. J.
, Yang
, G. Z.
, Wilkes
, A. J.
, Mohiaddin
, R. H.
, Firmin
, D. N.
, and Yacoub
, M. H.
, 2000
, “Asymmetric redirection of flow through the heart
,” Nature (London)
, 404
, pp. 759
–761
.12.
Fujimoto
, S.
, Mohiaddin
, R. H.
, Parker
, K. H.
, and Gibson
, D. C.
, 1995
, “Magnetic resonance velocity mapping of normal human transmitral velocity profiles
,” Heart Vessels
, 10
, 236
–240
.13.
Kim
, Y. H.
, Walker
, P. G.
, Pedersen
, E. M.
, Poulsen
, J. K.
, Oyre
, S.
, Houlind
, K.
, and Youganathan
, A. P.
, 1995
, “Left ventricular blood flow patterns in normal subjects: a quantitative analysis by 3-D magnetic resonance velocity mapping
,” J. Am. Coll. Cardiol.
, 26
, 224
–238
.Copyright © 2003
by ASME
You do not currently have access to this content.