The aim of this work is to describe and validate a technique for measuring the posture of all the segments of the hand in a non-invasive way. The technique uses digital photographic images to reconstruct 3-D location of markers drawn on the skin. The markers are defined to obtain joint rotation angles with physiological meaning. Different experiments have been developed in order to analyze the accuracy and repeatability of the angle measurements. Although the placement of markers does not require any special care, the errors due to their location are lower than 2.6 deg in all cases, thus assuring the repeatability of the technique.

1.
Dubousset, J. M. 1981, The Digital Joints. (In: Tubiana, R., ed. ‘The hand. Volume 1’.) Philadelphia: Saunders Company, pp. 191–201.
2.
Kapandji, I. A. 1997, Physiologie Articulaire, 1: Membre Supe´rieur. Paris: Maloine.
3.
Brand P. W., and Hollister, A. M., 1992, Clinical Mechanics of the Hand. Second Edition. St. Louis: Mosby-Year Book, Inc.
4.
Lee
,
J. W.
, and
Rim
,
K.
,
1991
, “
Measurement of finger joint angles and maximum finger forces during cylinder grip activity.
J. Biomech. Eng.
,
13
,
152
162
.
5.
Rash
,
G. S.
,
Belliappa
,
P. P.
,
Wachowiak
,
M. P.
,
Somia
,
N. N.
, and
Gupta
,
A.
,
1999
, “
A demonstration of the validity of a 3-D video motion analysis method for measuring finger flexion and extension.
J. Biomech.
,
32
,
1337
1341
.
6.
Yun, M. H., and Freivalds, A., 1998, Analysis of tool grip tasks using a 3D glove. (In: Kumar, S. ed. ‘Advances in Occupational Ergonomics and Safety 2’.) Amsterdam: IOS Press, 401–404.
7.
Hsiao
,
H.
,
Keyserling
,
W. M.
,
1990
, “
A three-dimensional ultrasonic system for posture measurement.
Ergonomics
,
33
(
9
),
1089
1114
.
8.
Small
,
C. F.
,
Pichora
,
D. R.
,
Bryant
,
J. T.
, and
Griffiths
,
P. M.
,
1993
, “
Precision and accuracy of bone landmarks in characterizing hand and wrist position.
J. Biomech. Eng.
,
15
(
5
),
371
378
.
9.
Speirs
,
A. D.
,
Small
,
C. F.
,
Bryant
,
J. T.
,
Pichora
,
D. R.
, and
Zee
,
B. Y.
,
2001
, “
Three-dimensional metacarpophalangeal joint kinematics using two markers on the phalanx.
Proc. Inst. Mech. Eng.
,
215
(
4
),
415
419
.
10.
Smutz
,
W. P.
,
Kongsayreepong
,
A.
,
Hughes
,
R. E.
,
Niebur
,
G.
,
Cooney
,
W. P.
, and
An
,
K. N.
1998
, “
Mechanical advantage of the thumb muscles.
J. Biomech.
,
31
,
565
570
.
11.
Small
,
C. F.
,
Bryant
,
J. T.
, and
Pichora
,
D. R.
,
1992
, “
Rationalization of kinematic descriptors for three-dimensional hand and finger motion.
J. Biomech. Eng.
,
14
(
2
),
133
141
.
12.
Altman
,
D. G.
, and
Bland
,
J. M.
,
1983
, “
Measurement in medicine: the analysis of method comparison studies.
The Statician
,
32
,
307
317
.
13.
Craig
,
S. M.
,
1992
, “
Anatomy of the joints of the fingers.
Hand Clin.
,
8
(
4
),
693
700
.
You do not currently have access to this content.