0
TECHNICAL BRIEFS

Sensitivity Analysis of the Conical-Shaped Equivalent Model of a Bolted Joint

[+] Author and Article Information
Noah D. Manring

Mechanical and Aerospace Engineering Department, University of Missouri–Columbia, Columbia, MO 65211

J. Mech. Des 125(3), 642-646 (Sep 04, 2003) (5 pages) doi:10.1115/1.1587747 History: Revised September 01, 2002; Revised February 01, 2003; Online September 04, 2003
Copyright © 2003 by ASME
Your Session has timed out. Please sign back in to continue.

References

Burguete, R. L. 1992, “Methods to Calculate Joint Stiffness: A Review and Classification of Joint Types,” Proceedings of the 11th International Conference on Offshore Mechanics and Arctic Engineering. The American Society of Mechanical Engineers, OMAE—Volume III-B, Materials Engineering. pp. 347–53.
Shigley, J. E., and Mitchell, L. D., 1983, Mechanical Engineering Design, 4th Edition. McGraw Hill, New York.
Dimarogonas, A. D., 2001, Machine Design, A CAD Approach, John Wiley & Sons, Inc. New York.
Norton, R. L., 2000, Machine Design, An Integrated Approach, 2nd Edition, Prentice Hall, Upper Saddle River, New Jersey.
Hamrock, B. J., Jacobson, B., and Schmid, S. R., 1999, Fundamentals of Machine Elements, McGraw Hill, New York.
Juvinall, R. C., and Marshek., K. M., Fundamentals of Machine Component Design, John Wiley & Sons, Inc. New York.
Shigley, J. E., and Mischke, C. R., 2001, Mechanical Engineering Design, 6th Edition, McGraw Hill, New York.
Osgood, C. C., 1979, “Saving Weight on Bolted Joints,” Mach. Des., October 25th.

Figures

Grahic Jump Location
Schematic of a bolted joint and its conical-shaped equivalent system
Grahic Jump Location
Dimensionless spring rate of the clamped material
Grahic Jump Location
Sensitivity of the bolted joint to small changes in the washer diameter, d⁁w. The cone angle ψ is 30 deg for this plot.
Grahic Jump Location
Sensitivity of the bolted joint to small changes in l over d ratio, β. The cone angle ψ is 30 deg for this plot.
Grahic Jump Location
Sensitivity of the bolted joint to small changes in the cone angle, ψ. The nominal cone angle is 30 deg for this plot.
Grahic Jump Location
A plot of the error, ε, from Eq. (8). To make this plot, k⁁m was calculated using ψ=35 deg and k⁁mo was calculated using ψ=30 deg.

Tables

Errata

Discussions

Some tools below are only available to our subscribers or users with an online account.

Related Content

Customize your page view by dragging and repositioning the boxes below.

Related Journal Articles
Related eBook Content
Topic Collections

Sorry! You do not have access to this content. For assistance or to subscribe, please contact us:

  • TELEPHONE: 1-800-843-2763 (Toll-free in the USA)
  • EMAIL: asmedigitalcollection@asme.org
Sign In